Program management13.12 Backing up dataMilling520 Operating Manual, 03/2010, 6FC5398-7CP20-1BA08. Press "OK".The "Generate Archive: Name" window opens.9. Select the format (e.g. archive ARC (binary format)), enter the desiredname and press the "OK" softkey.A message informs you if archiving was successful.13.12.2 Generating the archive via series startupIf you only want to backup specific data, then you can select the desired files directly fromthe data tree and generate an archive.Archive formatsYou have the option of saving your archive in the binary and punched tape format.You can display the contents of the selected files (XML, ini, hsp, syf files, programs) in apreview.You can display information about the file, such as path, name, date of creation and change,in a Properties window.PreconditionThe access rights depend on the relevant areas and range from protection level 7 (keyswitch position 0) to protection level 2 (password: Service).Storage locations● CompactFlash Card under/user/sinumerik/data/archive, or/oem/sinumerik/data/archive● All configured logical drives (USB, network drives)Software optionIn order to save archives on the CompactFlash Card in the user area yourequire the "Additional 256 MB HMI user memory on CF card of NCU"option.NOTICEUSB FlashDriveUSB FlashDrives are not suitable as persistent memory media.