MillingOperating Manual, 03/2010, 6FC5398-7CP20-1BA0 543Easy Message (828D only) 1616.1 OverviewEasy Message enables you to be informed about certain machine states by means of SMSmessages via a connected modem:● For example, you would like to be informed about emergency stop states● You would like to know when a batch has been completedControl commands● HMI commands are used to activate or deactivate a user.Syntax: [User ID] deactivate¸ [User ID] activate● A special area is reserved in the PLC to which you can send commands in the form ofPLC bytes using SMS commands.Syntax: [User ID] PLC DataByteThe user ID is optional and required only if a corresponding ID has been specified in theuser profile. The string PLC indicates that a PLC byte is to be written. It is followed by thedata byte to be written in the following format: Base#Value. Base can take the values 2,10 and 16 and defines the number base. Then follows the separator # and the value ofthe byte. Only positive values are allowed to be sent.Examples:2#1110110110#3416#AFMachine manufacturerPlease refer to the machine manufacturer's specifications.Active usersIn order to receive an SMS message for certain events, you must be activated as user.User logonAs registered user, you can log on via SMS to inquire about messages.Action logYou can obtain precise information about incoming and outgoing messages via SMS logs.