R 02/92 General Function DescriptionI Note 1 (for positive values): IId Total track area mloo~,ooI II i i[ + lncreasing~values ITraversing direction I YII Ih Decreasinalvalues — II Traversing direction66 ,,1“o” Track identifier bit (A= 100, E = 200)“ ,,1 Track identifier bit (E = 100, A = 200)“o”99100 199Aside from the traversing direction the following applies:When the first cam value in traversing direction is reached, the track identifier bit is set (or resetrespectively).When the cam end is reached in the same direction, the track identifier bit by then is already reset(or set respectively).tions, the end value (or the initial value respectively) must be increased by one.1 – 91P 241 Equipment Manual@ SiemenS AG 1989, Order No: 6ES5 998-0KD21Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com