RUGGEDCOM ROX IIUser GuideChapter 3Device ManagementEnabling/Disabling Controlled Bypass for M12 LineModules 83Parameter Descriptiondetected-module The installed module's type specifier.Module Type Sets the module type to be used in this slot.Admin State Sets the administrative state for a module. Enabling the module powers it on.4. Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OKto proceed.NOTEUpon committing the new line module configuration, Internal Configuration Error alarms may begenerated. These can be safely ignored and cleared in this context.5. Click Exit Transaction or continue making changes.Section 3.16.5Enabling/Disabling Controlled Bypass for M12 Line ModulesControlled bypass is used to allow Ethernet traffic to bypass a defective unit in a network chain while preventingthe loss of data.21 3 6 74 5Figure 85: Sample Controlled Bypass Diagram1. Ethernet Traffic Generator 2. Router 1 3. Defective Router 4. M12 Line Module Port 1 5. M12 Line Module Port 2 6. Router 27. Receiving TrafficNOTEAn M12 line module with bypass control is required for this feature.To enable or disable controlled bypass for M12 line modules, do the following:1. Log in to the defective router.2. Change the mode to Edit Private or Edit Exclusive.3. Navigate to chassis » line-modules » {module} » bypass, where {module} is the M12 line module. TheBypass Control and Status form appears.