Line Modules Booksize4.4 Active Line Modules with cold plateBooksize Power UnitsManual, (GH2), 04/2014, 6SL3097-4AC00-0BP6 211Help with the mechanical control cabinet design is available from:Siemens AGIndustry Sector, IA DT MC MF - WKC ASTCCCC (Technical Competence Center Cabinets Chemnitz)Postfach 112409070 Chemnitz, Germanye-mail: cc.cabinetcooling.aud@siemens.comProperties of the heat sinkWe recommend using AlMgSi 0.5 as the heat sink material.The roughness of the external heat sink surface should be at least Rz 16. The contactsurface between the heat sink and cold plate should have an evenness of 0.2 mm(applicable to a height of 450 mm and a width of 300 mm).NoteMachine manufacturers can adapt the heat sink version to their special requirements. Thespecified rated data for the Line Modules can only be achieved if the power losses can bedissipated by the external heat sink under the specified general conditions.NOTICEDamage to the cold plate caused by incorrect mountingThe screw bolts can be damaged when mounting the cold plate.• Do not damage the cold plate.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com