Line connection and line-side power components3.8 Line reactorsBooksize Power Units102 Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP63.8.4.4 Technical dataTogether with the HFD line reactor, an external resistor must be used for damping purposes(refer to Chapter Wiring with the HFD line reactor (Page 103)).Table 3- 16 Technical data for HFD damping resistorsOrder number 6SN1113-1AA00-0DAx 1) 6SL3100-1BE21-3AAx 2) 6SL3100-1BE22-5AAx 3)Rated power [W] 300 800 1500Connection cable [m],included in scope of delivery3 5 5Connection 3 x 1.5 mm2 4 x 1.5 mm2 4 x 1.5 mm2Weight [kg] 1,45 5,5 5,6Degree of protectionaccording to EN 60529IP54 IP51 IP20UL file E-228809 E-212934 E-192450Ambient temperature [°C] 0 ... 55Dimensions (W x H x D)[mm]80 x 210 x 53 277 x 552 x 75 193 x 410 x 2401) The 300 W damping resistor can be used for HFD applications if the following is true after a heat run when all axes areshut down in a regulated way:- After an operating period of over two hours, the surface temperature of resistor 6SN1113-1AA00-0DA0 must notexceed 150° C.- This heat run must be repeated if the hardware configuration, e.g. motor cable lengths, is changed!2) Preferred type3) Alternatively possibleNoteUse of the 800 W damping resistor is preferable.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com