Sharp SPC1034 Instructions And Warranty
Atomic Wall ClockInstructions & WarrantyThank you for your purchase of this quality clock. The utmost care has gone into the design and manufacture of yourclock. Please read these instructions and store them in a safe place for future reference.The receiver unit has a clear, easy-to-read display that shows indoor temperature, outdoor temperature,time, month,date, day. The remote sensor transmits the outdoor temperature. To receive the outdoor temperature, place thesensor anywhere within 30 meters; the 433.92MHz technology means no wire installation is required.The Atomic Clock will always be accurate to within one second as it receives daily WWVB updates. Daylight SavingTime also automatically updates so there is no need to re-set the clock manually!IMPORTANT: If the Atomic Clock does not receive the WWVB signal immediately, wait overnight and it will beset in the morning.The clock has a built in receiver that automatically synchronizes itself with the WWVB radio signal broadcast by theUS Government’s National Institute of Standards & Technology (NIST) in Fort Collins, Colorado.FEATURES:Atomic Clock1The WWVB radiosignal daily broadcast ensures that the atomic clock will always display the most accurate date and time.. CLOCK DISPLAY:- Displays time in hours and minutes; calendar display of month, date & day; indoor temperature; outdoortemperature; signal strength indicator; daylight saving (DST).2. UP / WAVE / 12/24 BUTTON:- In the TIME / CALENDAR setting mode, press it to increase the setting values. Hold the button for 3 seconds,the display will change rapidly.- In normal mode, press and hold the button for 3 seconds for receive the RCC signal immediately.- During the RCC receiving period, press the button again to stop the RCC reception.- In normal mode, press the button to switch 12/24 time display format.3. DOWN / ℃/℉ BUTTON:- In the TIME / CALENDAR setting mode, press the button to decrease the setting values. Hold the button for 3seconds, the display will change rapidly.- In normal mode, press the button to switch temperature unit ℃/℉.4. ENTER / CHANNEL BUTTON:- In the TIME / CALENDAR setting mode, press the button to confirm the setting.- In normal mode, press the button to switch the between channel 1, 2 and 3 to receive the 433.92MHz signal;press and hold the button for 3 seconds will pairing with the outdoor remote sensor.5. DST SWITCH:- In normal mode, slide the switch to ON/OFF the DST function.6. WALL MOUNT7. SETTING SWITCH:- In normal mode, slide the switch to select different setting mode (LOCK/TIME SET/CALENDAR SET).SPC1034REMOTE TRANSMITTERRecommended operating range: -10℃ to 60℃, -50℉ to 140℉Resolution: 0.1℃/℉(above 0℃/32℉), 1℃/℉(below 0℃/32℉)Humidity measuring range: 20% RH to 95%RHOperating range: 20% RH to 95%RHResolution: 1%RHRF transmission frequency: 433.92MHzRemote transmitter: 1 unitRF transmission range: maximum 30 metersTemperature sensing cycle: around 50 secondsPOWERMain unit: 4.5V, use 3 x AA 1.5V alkaline batteryRemote transmitter: 3V, use 2 x AA 1.5V alkaline batteryDIMENSIONMain unit: 280(W) x 178(H) x 22(D)mm11.0(W) x 7.0(H) x 0.86(D)inchRemote transmitter: 40(W) x 130(H) x 24(D)mm1.6(W) x 5.1(H) x 0.9(D)inchFCC INFORMATION:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 ofthe FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentialinstallation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouragedto try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.- Consult the dealer or an experienced radio/TV technician for help.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void theuser's authority to operate the equipment. 1234678951011 |
Related manuals for Sharp SPC1034
Sharp SPC1038 Instructions & Warranty
Sharp SPC1100 Instructions & Warranty
Sharp SPC1100 Instructions & Warranty
Sharp SPC1107 Instructions & Warranty
Sharp SPC936 Instructions & Warranty
Sharp SPC562 Instructions & Warranty
Sharp SPC315 Instruction Manual & Warranty
Sharp Accu-Set SPC1010ODX Instruction Manual & Warranty
Sharp SPC906 Instruction Manual
Sharp SPC900 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved