Value Range • Y (Enable dial plan filtering)• N (Disable dial plan filtering)Note• If set to "Y", the dialed number will not be sent to the line whenthe number dialed by the user does not match any of the dialformats specified in the dial plan.• If set to "N", the dialed number will be sent to the line, even ifthe number dialed by the user does not match any of the dialformats specified in the dial plan.Default Value NWeb User Interface Reference Call Even If Dial Plan Does Not Match (Page 128)MACRODIGIT_TIMValue Format INTEGERDescription Specifies the length of time, in seconds, that the unit waits when a "T"or "t" has been entered in the dial plan.Value Range 1–15Default Value 5Web User Interface Reference Timer for Dial Plan (Page 120)INTERNATIONAL_ACCESS_CODEValue Format STRINGDescription Specifies the number to be shown in the place of the first "+" symbolwhen the phone number for incoming international calls contains "+".Value Range Max. 8 characters (consisting of 0–9, *, and #)Note• No other characters are allowed.Default Value Empty stringWeb User Interface Reference International Call Prefix (Page 121)COUNTRY_CALLING_CODEValue Format STRINGDescription Specifies the country/area calling code to be used for comparativepurposes when dialing a number from the incoming call log thatcontains a "+" symbol.Value Range Max. 8 characters (consisting of 0–9)258 Administrator Guide Document Version 2015-025.3.29 Call Control Settings