Chapter 3 Preparation — Setting of time data- 45 -∫ Setting range of time codeThe range of the time code that can be set differs depending on the frame rate of [REC FORMAT].@ NOTE0 The set change is not reflected if the time code setting screen is closed without confirming the setting value.0 Set the number of frames with a value that is a multiple of 4 when the frame rate of [REC FORMAT] is set to 23.98p. The recorded time code will shiftwith any other value.0 In the following cases, [DF/NDF] is fixed to [NDF]:j When the frame rate of the [REC FORMAT] is 23.98pj When interval recording is enabledTime code function during battery replacementThe operation of the time code generator will continue by the backup mechanism functioning even when replacing the battery.The time code of the free run may shift when any item in the [SYSTEM] menu → [FREQUENCY], [FILE FORMAT], or [REC FORMAT] is changed.After turning on the power again with the power button, check the time code and set again if necessary.Time code in super slow recordingThe time code is fixed to [REC RUN] when the super slow recording function is enabled.≥ The time code output from the terminal* or the terminal proceeds at 1× speed starting at the same time as recording.* Available for use when using / .[FREQUENCY] Frame rate of [REC FORMAT] Range of the time code that can be set[59.94Hz] 59.94p, 29.97p, 59.94i 00:00:00:00 to 23:59:59:2923.98p 00:00:00:00 to 23:59:59:23[50.00Hz] 50.00p, 25.00p, 50.00i 00:00:00:00 to 23:59:59:24CX8 CX10