Section 2 Installation InstructionsPart Number 000000966 03/09 2-9Location of Ice MachineThe location selected for the ice machine must meet thefollowing criteria. If any of these criteria are not met,select another location.• The location must be free of airborne and othercontaminants.• The air temperature must be at least 35°F (1.6°C),but must not exceed 110°F (43.4°C).• Remote air cooled - The air temperature must be atleast -20°F (-29°C), but must not exceed 120°F(49°C)• The location must not be near heat-generatingequipment or in direct sunlight and must be protectedfrom weather.• The location must not obstruct air flow through oraround the ice machine. Refer to the chart below forclearance requirements.Ice Machine Heat of RejectionIce machines, like other refrigeration equipment, rejectheat through the condenser. It is helpful to know theamount of heat rejected by the ice machine when sizingair conditioning equipment where self-contained air-cooled ice machines are installed.This information is also necessary when evaluating thebenefits of using water-cooled or remote condensers toreduce air conditioning loads. The amount of heat addedto an air conditioned environment by an ice machineusing a water-cooled or remote condenser is negligible.Knowing the amount of heat rejected is also importantwhen sizing a cooling tower for a water-cooledcondenser. Use the peak figure for sizing the coolingtower.S300 Self-ContainedAir-CooledSelf-ContainedWater-CooledTop/Sides 16" (40.6 cm) 8" (20.3 cm)Back 5" (12.7 cm) 5" (12.7 cm)S320/S450/S500/S600/S850/S1000Self-ContainedAir-CooledWater-Cooled andRemote*Top/Sides 8" (20.3 cm) 8" (20.3 cm)Back 5" (12.7 cm) 5" (12.7 cm)S420 Self-ContainedAir-CooledWater-Cooled andRemote*Top/Sides 12" (30.5 cm) 8" (20.3 cm)Back 5" (12.7 cm) 5" (12.7 cm)S1200 Self-ContainedAir-CooledWater-Cooled andRemote*Top 8" (20.3 cm) 8" (20.3 cm)Sides 12" (30.5 cm) 8" (20.3 cm)Back 5" (12.7 cm) 5" (12.7 cm)S1400/S1600/S1800 Self-ContainedAir-CooledWater-Cooledand Remote*Top/Sides 24" (61.0 cm) 8" (20.3 cm)Back 12" (30.5 cm) 5" (12.7 cm)*There is no minimum clearance required for water-cooled or remote icemachines. This value is recommended for efficient operation and servicingonly.**S3300 - 24” on all sides is recommended to allow access without moving thebin/ice machine.S3300** Water-CooledTop/Sides 8" (20.3 cm)Back 24" (61.0 cm)! CautionThe ice machine must be protected if it will besubjected to temperatures below 32°F (0°C).Failure caused by exposure to freezingtemperatures is not covered by the warranty. See“Removal from Service/Winterization”.SeriesIce MachineHeat of RejectionB.T.U./HourAir ConditioningBecause the heat of rejection varies during the ice making cycle,the figure shown is an average.PeakS300 5000 6000S320 3800 6000S420 5900 6900S450 5900 6900S500 6100 6900S600 9000 13900S850 13000 16000S1000 17700 21000S1200 20700 24500S1400 25000 28000S1600 21000 31000S1800 31000 36000S3300 45000 51000