Page 8Find us at www.keysight.comApplication software 1 (Continued)The S93xxxB software products replace the S93xxxAs, and the S93xxxAs will be discontinued in June 2019.Description For PNA-XSeries For PNASeries For PNA-LSeries Additional informationSpectrum analysis, up to 8.5 GHz 2 S930900B/A S930900B/A S930900B/ASpectrum analysis, up to 13.5 GHz2 S930901B/A S930901B/A S930901B/ASpectrum analysis, up to 26.5 GHz 2 S930902B/A S930902B/A S930902B/ASpectrum analysis, up to 43.5 GHz 2 S930904B/A S930904B/A S930904B/ASpectrum analysis, up to 50 GHz 2 S930905B/A S930905B/A S930905B/ASpectrum analysis, up to 67 GHz 2 S930907B/A S930907B/A N/ASpectrum analysis, up to 90 GHz 2 S930909B/A S930909B/A N/ASpectrum analysis, up to 120 GHz S93093B/A S93093B/A N/ASpectrum analysis, beyond 120 GHz S93094B/A S93094B/A N/AActive hot parameters S93110B/A N/A N/A Requires a 4-port test set option (4xx)Low-frequency extension (LFE) is disabled with Option 425Active hot parameters S93111B/A N/A N/A Export-restricted version for N5247B with maximum operationto 50 GHzRequires a 4-port test set Option (4xx)Low-frequency extension (LFE) is disabled with Option 425Fast CW measurements S93118B/A S93118B/A N/ATrue-mode stimulus S93460B/A S93460B/A N/A Requires a 4-port test set option (4xx)N-port measurements 3 S93551B/A 4 S93551B/A S93551B/A Not available with test set options 200, 210, 400, and 410Nonlinear vector network analysis 5Nonlinear component characterization S94510A 6 N/A N/A Requires test set option 41x or 42xNonlinear component characterization S94511A 6 N/A N/A Export-control version. Requires test set option 41x or 42xNonlinear X-parameters 8, 9 S94514A 7 N/A N/A Requires test set option 42x and application software S94510Aor S94511ANonlinear pulse-envelope domain S94518A N/A N/A Requires hardware option 021 and application softwareS94510A or S94511A, and S93025B/A or S93026B/AArbitrary load-impedance X-parameters 8, 9 S94520A N/A N/A Requires application software S94514A and an additionalload-control applicationArbitrary load-control X-parameters 8, 9, 12 S94521A N/A N/A Requires application software S94520AArbitrary load-control device characterization 10, 11, 12 S94522A N/A N/A Requires application software S94510A or S94511A1. The S9xxxxA software license types are fixed-perpetual (1FP), transportable-perpetual (1TP), fixed-1-year (1FY), and transportable-1-year (1TY). The S93xxxB softwarehas four license types: Node-locked, Transportable, USB Portable and Floating/Network, and has four term choices for each perpetual and time-based types. Please referto “Keysight Software Licensing Options, Provide Flexibility and Support” on page 29 for more details. (Note: S93093B/A, S93094B/A, S93898B/A, S93110B/A, S94510Aand S94511A have fixed-license types only). The fixed-perpetual (1FP) is the only license type that can be ordered as part of the instrument and installed. The other licensetypes must be ordered separately and installed from the web after the receipt of the instrument.2. For use with PNA or PNA-X models, a test set with internal receiver attenuators is recommended to avoid receiver compression when measuring large input signals. Foruse with PNA-L models, test set option 216 or 416 is recommended so that external attenuators can be connected via the front-panel jumpers to avoid receiver compressionas needed.3. When ordering a test set, select an appropriate interface kit. Refer to Multiport Measurements section on page 32 for more details.4. When N524xB is configured as a multiport analyzer using S93551B/A and a multiport test set, the combiner feature of Option 22x or 42x is temporarily disabled.When configured as a standalone analyzer, the combiner feature is enabled.5. A fully configured NVNA system requires two comb generators with power supplies, Keysight calibration kits (mechanical or ECal), and a power meter and sensor or USBpower sensor.6. Pulse capability requires option 021 and S93025B/A or S93026B/A.7. Pulse capability requires option 021, 022 and S93025B/A or S93026B/A.8. Requires EXG, MXG, or PSG signal generator for X-parameter extraction (the PNA-X’s 10 MHz reference output can be used for 10 MHz tone-spacing applications).9. X-parameters is a trademark and registered trademark of Keysight Technologies in the U.S., Europe, Japan, and elsewhere. The X-parameters format and underlyingequations are open and documented. For more information, visit www.keysight.com/find/eesof-x-parameters-info.10. Currently CW stimulus only.11. Use of this application will generally require external sources, couplers attenuators, wafer probe station and more to complete system configuration. Please work with yourlocal Keysight application engineer for details.12. Requires Win 7 OS or above.PNA Family Network Analyzer Configurations (Continued)PNA-X Series PNA Series PNA-L Series Test Port ConnectorN5249B 900 Hz/10 MHz to 8.5 GHz N5239B 300 kHz to 8.5 GHz 3.5 mm (male)N5241B 900 Hz/10 MHz to 13.5 GHz N5221B 900 Hz/10 MHz to 13.5 GHz N5231B 300 kHz to 13.5 GHz 3.5 mm (male)N5242B 900 Hz/10 MHz to 26.5 GHz N5222B 900 Hz/10 MHz to 26.5 GHz N5232B 300 kHz to 20 GHz 3.5 mm (male)N5244B 900 Hz/10 MHz to 43.5 GHz N5224B 900 Hz/10 MHz to 43.5 GHz N5234B 10 MHz to 43.5 GHz 2.4 mm (male)N5245B 900 Hz/10 MHz to 50 GHz N5225B 900 Hz/10 MHz to 50 GHz N5235B 10 MHz to 50 GHz 2.4 mm (male)N5247B 900 Hz/10 MHz to 67 GHz N5227B 900 Hz/10 MHz to 67 GHz 1.85 mm (male)