This information is subject to change without notice. © Keysight Technologies, 2019, Published in USA, February 1, 2019, 5992-1465ENPage 47Find us at www.keysight.comLearn more at: www.keysight.comFor more information on Keysight Technologies’ products, applications or services,please contact your local Keysight office. The complete list is available at:www.keysight.com/find/contactus1. All spare drives use solid-state storage. For more information, refer tona.support.keysight.com/pna/hdnumbers.html.2. For the latest guide to power meters and power sensors, refer to theKeysight web site: www.keysight.com/find/powermeters.3. 5063-1555 is a complete rack mount kit with handles. N52xxB comeswith ruggedized handles, which must be replaced with classic handlesshipped with the rack mount kit.General Accessories (Continued)Comb generatorsTwo are required for NVNA. Also requires separate power supply.– U9391C 10 MHz to 26.5 GHz comb generator– U9391F 10 MHz to 50 GHz comb generator– U9391G 10 MHz to 67 GHz comb generatorAmplifiers– 83006A power amplifier, 10 MHz to 26.5 GHz, 20 dB gain,power out: +18 dBm to 10 GHz or +16 dBm to 20 GHz or+14 dBm to 26.5 GHz– 83017A power amplifier, 50 MHz to 26.5 GHz, 25 dB gain,power out: +20 dBm to 20 GHz, or +15 dBm to 26.5 GHz– 83018A power amplifier, 2 to 26.5 GHz, 27 dB gain to 20GHz or 23 dB to 26.5 GHz, power out: +24 dBm to 20 GHz or+21 dBm to 26.5 GHz– 83020A power amplifier, 2 to 26.5 GHz, 30 dB gain to20 GHz or 27 dB to 26.5 GHz, power out: +30 dBm to 20 GHzor +26 dBm to 26.5 GHzEquipment rack accessories– E3663AC Rail kit (included with Option 1CM and 1CP)– 1CM042A Rack mount flange kit, for use without handles(included with Option 1CM)– 5063-1555 Rack mount flange kit with handles(included with Option 1CP) 3MonitorsAny VGA-compatible monitor can be connected directly to therear panel. Monitors with other video interfaces (for example,HDMI or DisplayPort) require USB-based video adapters (mustbe supplied by the user). Touch-screen monitors are supported.Interface cablesChoose the appropriate cables to connect each peripheral to thenetwork analyzer.– 10833A GPIB cable, 1.0 m (3.3 ft)– 10833B GPIB cable, 2.0 m (6.6 ft)– 10833D GPIB cable, 0.5 m (1.6 ft)– 82357B GPIB to USB interface– 83050A power amplifier, 2 to 50 GHz, 23 dB gain, power out:+20 dBm to 40 GHz or +17 dBm to 50 GHz– 83051A power amplifier, 45 MHz to 50 GHz, 23 dB gainpower out: +12 dBm to 45 GHz or +10 dBm to 50 GHzCouplers– 87300B coaxial coupler, 1 to 20 GHz, SMA (f), 10 dBcoupling– 87300C coaxial coupler, 1 to 26.5 GHz, 3.5 mm (f), 10 dBcoupling– 87301B coaxial coupler, 10 to 46 GHz, 2.92 mm (f), 10 dBcoupling– 87301D coaxial coupler, 1 to 40 GHz, 2.4 mm (f) or optional2.92 mm (f), 13 dB coupling– 87301E coaxial coupler, 2 to 50 GHz, 2.4 mm (f), 10 dBcoupling– 87310B 90o coaxial coupler, 1 to 18 GHz, SMA (f), 3 dBcoupling