Page 44Find us at www.keysight.com1. Special rugged female connector specifically for connecting to thenetwork analyzer test port, but does not mate with a standard maleconnector.2. The PNA Series must have firmware revision A.12.85.00 or above for theoperation with the N469xD Series ECal.For devices with Type-N connectorsMechanical calibration kits85054B standard: DC to 18 GHz. Includes:– 00909-60011 Type-N (m) fixed lowband load– 00909-60012 Type-N (f) fixed lowband load– 85054-60025 Type-N (m) short– 85054-60026 Type-N (f) short– 85054-60027 Type-N (m) open– 85054-60028 Type-N (f) open– 85054-60031 Type-N (f) to 7mm adapter– 85054-60032 Type-N (m) to 7mm adapter– 85054-60037 Type-N (f) to Type-N (f) adapter– 85054-60038 Type-N (m) to Type-N (m) adapter– 85054-80010 Type-N (f) sliding load– 85054-80009 Type-N (m) sliding load– 85054-60050 Type-N (f) connector gage– 85054-60052 Type-N (f) gage master– 85054-60051 Type-N (m) connector gage– 85054-60053 Type-N (m) gage master85054D economy: DC to 18 GHz. Includes:– 85054-60025 Type-N (m) short– 85054-60026 Type-N (f) short– 85054-60027 Type-N (m) open– 85054-60028 Type-N (f) open– 85054-60031 Type-N (f) to 7mm adapter– 85054-60032 Type-N (m) to 7mm adapter– 85054-60037 Type-N (f) to Type-N (f) adapter– 85054-60038 Type-N (m) to Type-N (m) adapter– 85054-60046 Type-N (m) fixed load– 85054-60047 Type-N (f) fixed loadAdapter sets– 85130C 3.5 mm to Type-NElectronic calibration kitsN4431B Microwave ECal: 300 kHz to 13.5 GHz, 4-ports. Includes:– Option 020 module with: N4431-60007 4 x Type-N (f) ECalmoduleN4432A Microwave ECal: 300 kHz to 18 GHz, 4-ports. Includes:– Option 020 module with: N4432-60003 4 x Type-N (f) ECalmoduleN4432A-xxx mixed-connector options:Connector type Port AoptionPort BoptionPort CoptionPort Doption3.5 mm (f) 101 201 301 4013.5 mm (m) 102 202 302 402Type-N 50 ohm (f) 103 203 303 403Type-N 50 ohm (m) 104 204 304 404Option 150: Replaces standard storage container with a woodenboxN4690B Microwave ECal: 300 kHz to 18 GHz, 2-ports. Includes:– Option M0F module with: N4690-60004 Type-N (f) toType-N (m) ECal module– Option 00M module with: N4690-60005 Type-N (m) toType-N (m) ECal module– Option 00F module with: N4690-60006 Type-N (f) to Type-N(f) ECal module– Option 00A adds:– 85054-60037 Type-N (f) to Type-N (f) adapter– 85054-60038 Type-N (m) to Type-N (m) adapterN4690D 2 Microwave ECal: DC or 300 kHz to 18 GHz, 2-ports.Includes:– Option F0F: Both connectors are Type-N 50 Ω female onmodule– Option M0F: 1 female and 1 male Type-N 50 Ω connector onmodule– Option M0M: Both connectors are Type-N 50 Ω male onmodule– Option 0DC: DC to 18 GHz– Option 003: 300 kHz to 18 GHz– Option 00A adds:– 85054-60037 Type-N (f) to Type-N (f) adapter– 85054-60038 Type-N (m) to Type-N (m) adapterCablesUse the test port cables recommended for devices with 7 mmconnectors, and 7 mm to Type-N adapters that are from the85054B/D Type-N calibration kit (see 7 mm connector section).Option 150: Replaces standard storage container with a woodenboxN4431B-xxx mixed-connector options:Connector type Port AoptionPort BoptionPort CoptionPort Doption3.5 mm (f) 101 201 301 4013.5 mm (m) 102 202 302 402Type-N 50 ohm (f) 103 203 303 403Type-N 50 ohm (m) 104 204 304 4047-16 (f) 1 105 205 305 4057-16 (m) 1 106 206 306 406Option 150: Replaces standard storage container with a woodenbox