English 5.906-565.0 Rev. 00 (12/12) 31 Dismantle the push handle (2 screws) and removeit. Remove pressure switch (see "Removing thepressure switch"). Loosen 4 screws. Opening the electric casing (see "Opening theelectric casing")1 Cord grip2 Screw Unscrew 2 screws. Remove the traction relief. Lift the electric casing and turn it around the rightpipe in an anti-clockwise direction. Loosen 4 screws. Remove the lid.cw: clockwise directionccw: anti-clockwise directionNote:Only use terminal assignment "cw"!7.20 Access to the terminal box of the elec-tric motor