22 English 5.906-565.0 Rev. 00 (12/12) Install a nozzle size 018 (special tool 5.765-092)on the spray lance. Install a pressure gauge (special tool) between thehigh-pressure connection and the high-pressurehose. Set up the power and water supply. Pull off the rotary handle.1 Rating nut2 Set screw3 Locknut Screw out the threaded pin. Loosen the lock nut and turn it all the way down. Turn on the appliance. Open the hand spray gun. Adjust the adjustment nut until the following work-ing pressure is displayed: Open and close the hand spray gun 3 times whilethe motor is running. Check the set pressure and readjust if necessary. Tighten the lock nut without moving the adjust-ment nut. Screw in the threaded pin and tighten it. Reinstall the original power nozzle on the spraylance. Completely unscrew the adjustment nut with therotary handle (in an anti-clockwise direction). Turn on the appliance. Working pressure of approx. 3 MPa (30 bar) is ap-plied. Open and close the hand spray gun 3 times whilethe motor is running. Completely screw in the adjustment nut with therotary handle (in a clockwise direction). Seal the adjustment nut and lock nut by means oflocking paint. Fit the rotary handle.7.12 Adjusting the overflow valveHD 6/15-4 16.0...16.4 MPa (160...164 bar)HD 7/11-4 12.0...12.4 MPa (120...124 bar)