HOWTO USEYOUR GENERATOR Generator LocationIf you haveany problems operating your generator after Generator Clearancereading the manual, please call the generator heipline at1-800-222-3136.System GroundThe generator has a system ground that connects thegenerator frame components to the ground terminals on theAO output receptacles.The system ground is connected tothe AO neutral wire (the neutral is bonded to the generatorframe).Special RequirementsThere may be Federalor State Occupational Safety andHealth Administration (OSHA)regulations, local codes, orordinances that apply to the intended use of the generator.Pleaseconsult a qualified electrician, electrical inspector, orthe local agency having jurisdiction.• In some areas, generators are required to be registeredwith local utility companies.• If the generator is used at a construction site, there maybe additional regulations which must be observed.Connecting to a Building's Electrical SystemOonnectionsfor standby power to a buiiding's electricalsystem must be made by a qualified electrician. Theconnection must isolatethe generator power from utilitypower, and must comply with all applicable laws andelectrical codes.WARNINGiGeneratorproduces hazardous voltage._¢ Failureto isolate generator from power utility canresult in death or injury to electric utility workersdue to backfeedof electrical energy.• Whenusinggeneratorfor backuppower,notifyutilitycompany.Useapprovedtransferequipmentto isolategeneratorfromelectricutility.• Usea groundfaultcircuit interrupter(GFCI)in anydamporhighlyconductivearea,suchasmetaldeckingor steelwork.• DONOTtouch barewiresor receptacles., DONOTusegeneratorwith electricalcordswhich areworn,frayed,bareor otherwisedamaged., DONOToperategeneratorin the rain or wet weather.• DONOThandlegeneratoror electricalcordswhilestandinginwater,whilebarefoot,or whilehandsor feet arewet.• DONOTallowunqualifiedpersonsor childrento operateorservicegenerator.WARNINGExhaustheat/gases can ignite combustibles,structures or damage fuel tank causing a fire.Keepat least5 ft. (1.5 m)clearanceon all sidesof generatorincludingoverhead.Placegenerator outdoors in an area that wiil not accumulatedeadly exhaust gas. DO NOTplace generator where exhaustgas (A) could accumulate and enter inside or be drawn into apotentially occupied building. Ensure exhaust gas is keptaway from any windows, doors, ventilation intakes, or otheropenings that can allow exhaust gas to collect in a confinedarea. Prevailing winds and air currents should be taken intoconsideration when positioning generator.Using a generator indoors CAN KiLL YOU iN MINUTES.Generator exhaust contains carbon monoxide. This isa poison you cannot see or smeJLNEVER use inside a homeor garage, EVEN IF doorsand windows are open.AOnJy use OUTSIDE andfar away from windows,doors, and vents.10