8. Slide up or down the left side of the Pre-Separation Plate to adjust the position between the Pre-Separation Plateand the Lifter Plate within L=+/-0.5 mm.NOTE:• Check the position scale on the left edge of the Pre-Separation Plate to record the adjusted value.• Check that plain paper passes smoothly.L=+/-0.5mm9. Fasten the 2 screws on the left loosened at procedure 7.2x5. Adjustment92