Chapter 55-25.2 User Error Code5.2.1 Alarm Code 0004-5177The machine flashes the original detection LED at intervals of 240 msec when it identifies a fault as being an alarm condition.T-5-3E413 The level of the locking HP sensor does not change within a specific period of time.Cause: there is a fault in the locking motor or the driver PCB; there is a fault in the locking HP sensor;there has been an increase in the load of the locking cam.0001 Read roller 1 open The level of the locking HP sensor does not change within aspecific period of time after the locking motor has been driven.0002 Read roller 1 close The level of the locking HP sensor does not change within aspecific period of time after the locking motor has been driven.Code Fault Descriptionxx03 Separation has failed. The 1st original does not reach the post-separation sensor.The 1st original does not reach the registration sensor.xx11 The number of jam recovery sheets isgreater than the number of originals.In jam recovery mode, the tray runs out of originals before asmany as 'the number of recovery sheets - 1' has been delivered.xx13 An original has been pulled out. The read sensor is off when the preceding original has beenmoved to a point of reading.xx14 High-speed duplexing operation fails. The original is longer than the specified limit.Code Detail code Item Description