2. Disconnect the Grounding Cable [1].• 2 Connectors [2]• 1 Screw [3]• 1 Wire Saddle [4]1x2x[1][4][3][2]3. Open the ADF.4. Remove the ADF [1].CAUTION:When holding this equipment, be careful not to touch the Platen roller [3].• 2 Screws [2]2x[1][3][2]Actions after Reinstalling the ADF1. Adjusting the Height.“Adjusting the Height” on page 702. Adjusting the Perpendicularity “Adjusting the Perpendicularity” on page 743. Adjusting the Reading Position“Adjusting the Reading Position” on page 784. Adjusting the Magnification“Adjusting the Magnification” on page 795. Adjusting the Image Position (Main Scanning Direction)“Adjusting the Image Position (Main Scanning Direction)”on page 806. Adjusting the Image Position (Sub Scanning Direction)“Adjusting the Image Position (Sub Scanning Direction)” onpage 817. Adjusting the White Level “Adjusting the White Level” on page 824. Parts Replacement and Cleaning43