7 Connection /commissioning (qualifiedpersonnel)HandscannerBCS 3600 ex series82 / 106 Subject to technical modificationsRevision A / 04/2019Testing the communication (RS232 or USB-SPP)The serial communication can be checked with the help of a terminal program.A serial interface does not have its own intelligence.This means that incoming data at the serial interface will be lost if there is no application available thatcan process incoming data.There is a large number of terminal programs on the market. E.g. Hyperterminal, Tera Term, Putty orothers.BARTEC does not distribute any terminal program or software keyboard wedge application.When using a universal power supply module, a software wedge or other application must beinstalled on the host PC for data transfer.The software wedge or other application serves to convert the incoming data as keyboard input andto enter the data into the currently active field on the host PC.Terminal ProgramThe test described below with a terminal program was performed with the H-Term application. Anyother terminal program that supports serial communication can be used alternatively.Test communication/data transmission1. Open Terminal program2. Select the serial interface to which the universal power supply module with coupledBCS 36x8ex is connected (In the example COM1).Can be checked in Device Manager