HandscannerBCS 3600ex series 4 Product descriptionSubject to technical modificationsRevision A / 04/2019 37 / 1064.6.4 Permissible core cross-sectionsDescription of the conductor Permissible core cross-sectionRigid 0.08 mm2 - 2.5 mm 2 28 – 14 AWGFlexible 0.08 mm 2 - 2.5 mm 2 28 – 14 AWGFlexible with wire end ferrule, without plasticsleeve0.25 mm 2 - 1.5 mm 2 24 – 16 AWGFlexible with wire end ferrule, with plasticsleeve0.25 mm 2 - 1.5 mm 2 24 – 16 AWGWire diameter (AWG) 28 - 12 kcmil 36 – 39 AWGTable 35 Permissible core cross sectionsPermissible connection cable diameterPossible cable dimensions for the cable gland onthe USMInterfaces Cable gland pipeline diameter Shield diameterUSB-SPP* Ex e M16x1,5(black)4,5-5,7mm 3-6 mmRS232 4,5-9mm 3-6 mmRS422 4,5-9mm 3-6 mmRS485 4,5-9mm 3-6 mmTable 36 Permissible connection cable diameter4.6.6 Terminals for outer conductorsTo connect the outer conductors to the terminals in hazardous areas, observe EN 60079-14 (Explosiveatmospheres - Part 14: Design, selection and installation of electrical systems). Connect the conductors according to the terminal assignment. Equipotential bonding is notnecessary because the power supply is electrically isolated.