Absolute Process Instruments API 1600 G Manual
AC Input Alarm Trips, Factory Ranged API 1600 G, API 1620 GInput: 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-900 mAACOutput: One 8 Amp DPDT Relay or Two 8 Amp SPDT RelaysApplicationsO Precision Internal AC/DC ConverterO Field Adjustable SetpointsO Plug-In Design for Fast InstallationO Input LoopTracker®and Alarm Status LEDsO Alarm Test ButtonQ Process Limit Backup AlarmQ Over, Under, Out-of-Range Voltage or Current AlarmQ Heater Break, Conveyor Jam AlarmModel Input Standard Alarm Configuration PowerAPI 1600 G Factory ranged, specifyAC voltage, mV or mA currentrangeSingle setpoint one DPDT relayHI alarm, normal acting115 VACAPI 1600 G A230 230 VACAPI 1600 G P 85-265 VAC or 60-300 VDCAPI 1600 G D 9-30 VDCAPI 1620 G Factory ranged, specifyAC voltage, mV or mA currentrange2 setpoints, 2 SPDT relaysHI/LO alarms, normal acting115 VACAPI 1620 G A230 230 VACAPI 1620 G P 85-265 VAC or 60-300 VDCAPI 1620 G D 9-30 VDCAC Input RangeFactory configured, please specify AC input rangeVoltage: 0-50 mVAC to 0-300 VACCurrent: 0-1 mAAC to 0-900 mAACSystem voltages must not exceed socket voltage ratingInput Impedance (Voltage Input)220 kΩ minimumInput Voltage Burden (Current Input)1.0 VRMS maximumInput Frequency40 Hz to 1000 Hz sinusoidalInput Protection, Common Mode750 VDC or 750 VACpLoopTrackerVariable brightness LED indicates input level and statusAPI 1600 G Relay OutputTwo SPDT form C contact sets operating in unison as oneDPDT contact setOne setpoint, 12 turn potentiometer, 0-100% of spanFactory configured alarm typeNormal acting alarmStandard: HI alarmOptional: LO alarmAPI 1620 G Relay OutputTwo independent SPDT form C contact setsTwo setpoints, two 12 turn potentiometers, 0-100% of spanNormal acting alarmsStandard: HI/LO alarmOptions: LO/LO, HI/HI, LO/HI alarmsInternal jumpers for HI/LO, LO/LO, HI/HI, LO/HIRelay Contact Rating8 A @ 240 VAC resistive load or 30 VDC resistive loadSee graph on other side for relay load ratingsCaution: Do not exceed socket voltage ratingUse an RC snubber for inductive loadsDeadbandAlarm trip/reset window are symmetrical about the setpointAPI 1600 G 1.0 to 100% of span, 12 turn potentiometerAPI 1620 G Fixed at 1% of span, standardAPI 1620 G A Adjustable deadbands, 1.0 to 100% of span,1 turn potentiometer for each setpointOutput Test ButtonToggles relay(s) to opposite state when pressedResponse Time70 milliseconds typicalAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than ±0.02% of span per °C stability, calculated, nottestedHousing and SocketsIP 40, requires installation in panel or enclosureAPI 011 or API 011 FS socketSocket mounts to 35 mm DIN rail or can be surface mountedPowerStandard: 115 VAC ±10%, 50/60 Hz, 2.5 W max.P option: 85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ.A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.D option: 9-30 VDC, 2.5 W typicalOptions—add to end of model numberL 1600 G with LO trip. Alarm trips on decreasing signal.HH 1620 G with HI/HI trip. Alarms trip at their respectivetrip points on increasing signal.LL 1620 G with LO/LO trip. Alarms trip at their respectivetrip points on decreasing signal.LH 1620 G with LO/HI trip instead of HI/LO.A 1620 G with adjustable deadbands.U Conformal coating for moisture resistanceAccessories—order as a separate line itemAPI 011 11-pin socket, DIN rail or surface mountAPI 011 FS 11-pin finger safe socket, DIN rail or surface mountAPI CLP1 Module hold-down spring for high vibration ormobile applicationsDescriptionThe API 1600 G and API 1620 G are factory configured for anAC voltage or current input and provide alarm contact outputs.Heavy duty relay contacts allow the module to directly controlhigh capacity loads.The API 1600 G provides a single setpoint adjustment andDPDT relay contacts. The alarm output is normal actingand can be factory configured for HI or LO operation. Top-accessible potentiometers are used to adjust the alarm setpointand deadband.The API 1620 G contains two independent setpoints with twoSPDT relay contact outputs. The alarm outputs are normalacting can be factory or user configured for HI/HI, HI/LO, LO/HIor LO/LO operation. Top-accessible potentiometers are used toadjust each alarm setpoint. Deadband is fixed at 1% of span.Adjustable deadbands are optional.LoopTracker and Alarm Status LEDsAPI exclusive features include a LoopTracker LED that varies inintensity with changes in the input signal.A red/green bi-color alarm status LED (two on the API 1620G) visually indicate alarm status. These LEDs provide a quickvisual picture of your process at all times.Output TestAPI’s exclusive functional test button can be used to verify thealarm and system operation. Press the Test button to togglethe alarm relay(s) to the opposite state. The output test but-ton greatly aids in saving time during initial startup and/ortroubleshooting.Free FactoryI/O Setup!Quick Linkapi-usa.com/1600API 1600 GVariable Brightness Input LEDBi-Color Relay LEDDeadband AdjustmentSetpoint AdjustmentOutput Test Button2.38"1.75"API 1620 GA Option Deadband Adjustments2.38"1.75"Variable Brightness Input LEDBi-Color Relay 2 LEDBi-Color Relay 1 LEDSetpoint 2 AdjustmentSetpoint 1 AdjustmentOutput Test ButtonAPI 1620 G P 001 001115 VACYour Required InputYour Alarm Configuration2.75"H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAHot SwappablePlug-In DesignAPI 011300 V RatingAPI 011 FS300 V Rating API CLP1© 09-21api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502AABSOLUTEBSOLUTE PPROCESSROCESS IINSTRUMENTSNSTRUMENTS |
Related manuals for Absolute Process Instruments API 1600 G
Absolute Process Instruments APD 4300 Manual
Absolute Process Instruments API 4400 G Quick Start Manual
Absolute Process Instruments API 7500 G Quick Start Manual
Absolute Process Instruments AP11400 G Quick Start Manual
Absolute Process Instruments API 4380 G HV3 Quick Start Manual
Absolute Process Instruments API 6380 G Series Quick Start Manual
Absolute Process Instruments APD 1401 Quick Start Manual
Absolute Process Instruments API 6380 G HV Series Quick Start Manual
Absolute Process Instruments APD 7580 Quick Start Manual
Absolute Process Instruments APD 6010 Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved