AC to DC Transmitters, Isolated, Field Rangeable API 6380 G SeriesInput: 0-50 mVAC to 0-250 VAC, 0-5 mAAC to 0-200 mAACOutput: 0-1 VDC to ±10 VDC, 0-2 mADC to 0-20 mADCO One Minute Setup for Hundreds of I/O RangesO External Switches & Tables for Range SelectionO Non-Interactive Zero and Span CalibrationO Full 2000 V Input/Output/Power IsolationO Input and Output LoopTracker®LEDsO Output Test ButtonO Built-In Loop Power Supply for mA OutputQ Convert AC Signals to DC Process SignalsQ Monitor Line Voltage or Current LevelsQ Isolate and Convert AC Signals for Panel Meters, PLCs,Recorders, Data Acquisition, DCS, & SCADA SystemsApplicationsModel Input Output Module PowerAPI 6380 GField configurable0-50 mVAC to 0-250 VAC0-5 mAAC to 0-200 mAACField configurable0-1 VDC to 0-10 VDC±1 VDC to ±10 VDC0-2 mADC to 0-20 mADC115 VACAPI 6380 G A230 230 VACAPI 6380 G P 85-265 VAC or 60-300 VDCAPI 6380 G D 9-30 VDCAPI 6380 G S Field configurableTrue RMS input measurement0-50 mVAC to 0-250 VAC0-5 mAAC to 0-200 mAACField configurable0-1 VDC to 0-10 VDC±1 VDC to ±10 VDC0-2 mADC to 0-20 mADC115 VACAPI 6380 G A230 S 230 VACAPI 6380 G P S 85-265 VAC or 60-300 VDCAPI 6380 G D S 9-30 VDCDescriptionThe API 6380 G accepts an AC voltage or current input and pro-vides an optically isolated DC voltage or current output that islinearly related to the input. Accuracy is maintained over a widefrequency range for maximum flexibility. A true RMS model API6380 G S is available for distorted AC inputs.The full 3-way (input, output, power) isolation makes this mod-ule useful for ground loop elimination, common mode signalrejection or noise pickup reduction.20 input and 16 output ranges can be field-configured viaexternal rotary and slide switches. Popular ranges are listedon the module label. Consult the factory for assistance withspecial ranges.LoopTrackerAPI exclusive features include two LoopTracker LEDs (green forinput, red for output) that vary in intensity with changes in theprocess input and output signals. These provide a quick visualpicture of your process loop at all times and can greatly aid insaving time during initial startup and/or troubleshooting.Output TestAn API exclusive feature includes the test button to provide afixed output (independent of the input) when held depressed.The test output level is potentiometer adjustable from 0 to100% of output span.The output test button greatly aids in saving time during initialstartup and/or troubleshooting.AC Input RangesField selectable ranges via switch settingsSystem voltages must not exceed socket voltage ratingVoltage: 0-50 mVAC to 0-250 VACCurrent: 0-5 mAAC to 0-200 mAACS option: True RMS input measurementSee API 6380 G 5A for current input ranges up to 0-5 AACInput ImpedanceVoltage (0-4 VAC): 1 MΩ minimumVoltage (>4 VAC): 220 kΩ minimumCurrent: 10 Ω typicalInput Frequency40 Hz to 1000 Hz sinusoidalInput Protection, Common Mode750 VDC or 750 VACpLoopTrackerVariable brightness LEDs indicate I/O loop level and statusDC Output RangesField selectable ranges via switch settingsVoltage: 0-1 VDC to 0-10 VDCBipolar Voltage: ±1 VDC to ±10 VDCCurrent: 0-2 mADC to 0-20 mADC20 V compliance, 1000 Ω at 20 mAOutput LogicNormal acting, internal jumper for output reversalOutput CalibrationMulti-turn zero and span potentiometers for output±15% of span adjustment range typicalOutput Loop Power Supply20 VDC nominal, regulated, 25 mADC, max. ripple <10 mVRMSOutput TestFront button sets output to test level when pressedPotentiometer adjustable 0-100% of spanOutput Ripple and NoiseLess than 10 mVRMSLinearityBetter than ±0.1% of spanAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than ±0.02% of span per °C stabilityResponse Time200 milliseconds typical (0-90%)Isolation2000 VRMS minimumFull isolation: power to input, power to output, input to outputInstallation EnvironmentIP 40, requires installation in panel or enclosureUse with API 008 or API 008 FS socketSocket mounts to 35 mm DIN rail or can be surface mountedUL 508C pollution degree 2 environments or betterPowerStandard: 115 VAC ±10%, 50/60 Hz, 2.5 W max.P option: 85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 WA230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.D option: 9-30 VDC, 2.5 W typicalFree FactoryI/O Setup!Quick Linkapi-usa.com/6380MinuteSetup!1Free Factory SetupSpecify I/O ranges if factory is to set switchesOption—add to end of model numberU Conformal coating for moisture resistanceAccessories—order as a separate line itemAPI 008 8-pin socket, DIN rail or surface mountAPI 008 FS 8-pin finger safe socket, DIN rail or surface mountAPI CLP1 Module hold-down spring for high vibration ormobile applications API 008600 V RatingAPI 008 FS300 V RatingAPI CLP1Socket SoldSeparately2.75"Hot SwappablePlug-In Design2.38"1.75"Variable BrightnessInput LEDOutput Test ButtonOutput Test AdjustOutput SpanOutput ZeroVariable BrightnessOutput LEDH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAE145968115 VAC, 230 VAC modelswith input up to 150 VAC© 08-19api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502ABSOLUTE PROCESS INSTRUMENTS