Absolute Process Instruments APD 4300 Manual
Dimensions0.89" W x 4.62" H x 4.81" D22.5 mm W x 117 mm H x 122 mm DHeight includes connectorsDC to DC Transmitters, Isolated, Factory Configured APD 4300Input: 0-100 mV to 0-300 VDC, Bipolar Voltages, 0-1 mA to 0-1000 mADCOutput: 0-1 V to ±10 VDC or 0-1 mA to 4-20 mAO Removable Plugs for Faster InstallationO Full 1200 V Input/Output/Power IsolationO Zero and Span Output Calibration PotentiometersO Input and Output LoopTracker® LEDsO Functional Test Button with Remote CapabilityO Built-In Loop Power Supplies for Input and OutputQ Convert, Boost, Rescale Process SignalsQ Isolate Single-Ended (Common Ground) PLC InputsQ Interface Process Signals with Panel Meters, PLCs,Recorders, Data Acquisition, DCS, and SCADA SystemsApplicationsOptions—add to end of model numberM01 Input/output reversal, such as 4-20 mA input to20-4 mA outputM09 High voltage output up to 20 V (specify range)DF Fast response time, consult factory.U Conformal coating for moisture resistanceAccessory—order as separate line itemAPI BP4 Spare 4-terminal plug, blackModel Input Output PowerAPD 4300 Factory configured—specifyinput rangeFactory configured—specifyoutput range85-265 VAC or 60-300 VDCAPD 4300 D 9-30 VDC or 10-32 VACAll models are factory rangedThe APD 4300 is configured to your specifications.Milliamp inputs and outputs can be field wired for sink orsource.How to OrderPlease specifyModelInput rangeOutput rangeOptions as requiredDescriptionThe APD 4300 accepts a DC voltage or current input and pro-vides an optically isolated DC voltage or current output that islinearly related to the input.Typical applications include signal isolation, conversion, boost-ing or a combination of the three. Full 3-way isolation (input,output, power) makes this module useful for ground loopelimination, common mode signal rejection or noise pickupreduction.The APD 4300 can be factory configured for 4-20 mA input and4-20 mA output to solve signal isolation, ground loop, commonmode, or noise pickup problems for non-isolated PLC inputs.For maximum versatility loop excitation power supplies areincluded for the input and output. A mA input and a mA outputcan be selectively wired for sinking or sourcing. This allows theAPD 4300 to work with any combination of sinking or sourcingmA transmitters and sinking or sourcing mA receiving devices.LoopTrackerAPI exclusive features include two LoopTracker LEDs (green forinput, red for output) that vary in intensity with changes in theprocess input and output signals. These provide a quick visualpicture of your process loop at all times and can greatly aid insaving time during initial startup and/or troubleshooting.Functional TestAn API exclusive feature includes the Functional Test Buttonto provide a fixed output (independent of the input) when helddepressed. The test output level is potentiometer adjustablefrom 0 to 100% of output span. The functional test buttongreatly aids in saving time during initial startup and/or trouble-shooting.The functional test can also be enabled with a customer-supplied external contact closure across terminals 5 and 6.This allows remote testing of the output or, for example, aPLC-controlled manual override setting.DC Input RangeFactory configured, please specify input range or consult fac-tory for special ranges.See table on other side for common ranges.Voltage: 0-100 mVDC to 0-300 VDCBipolar voltage: ±100 mVDC to ±10 VDCCurrent: 0-1 mADC to 0-1000 mADCInput Impedance (Voltage)200 kΩ minimumInput Voltage Burden (Current)1.25 VDC maximumCommon Mode Rejection120 dB minimumInput Loop Power Supply15 VDC nominal, regulated, 25 mADCMax. ripple, less than 10 mVRMSMay be selectively wired for sinking or sourcing mA inputLoopTrackerVariable brightness LEDs indicate I/O loop level and statusDC Output RangeFactory configured, specify output rangeVoltage, 10 mA max.: 0-1 VDC to 0-10 VDCVoltage, M09 option: 0-10 VDC to 0-20 VDCBipolar voltage: ±1 VDC to ±10 VDCCurrent: 0-1 mADC to 0-20 mADC20 V compliance, 1000 Ω at 20 mAOutput CalibrationMulti-turn zero and span potentiometers±15% of span adjustment range typicalOutput Loop Power Supply20 VDC nominal, regulated, 25 mADC, <10 mVRMS max. rippleMay be selectively wired for sinking or sourcing mA outputOutput Test/OverrideFront button sets output to test level when pressed or viaexternal contact closurePotentiometer adjustable 0-100% of spanOutput Ripple and NoiseLess than 10 mVRMS ripple and noiseLinearityBetter than ±0.1% of spanAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than ±0.04% of span per °C stabilityResponse TimeStandard: 70 milliseconds nominalDF option: Fast response time. Output noise levels will begreater than standard specifications. Consult factory.Isolation1200 VRMS minimumFull isolation: power to input, power to output, input to outputHousing and ConnectorsIP 40, requires installation in panel or enclosureFor use in Pollution Degree 2 EnvironmentMount vertically to a 35 mm DIN railFour 4-terminal removable connectors, 14 AWG max wire sizePower85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximumD versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximumRemovable PlugsSink or SourcemA OutputOutput LoopTrackerLEDInput LoopTrackerLEDZero and Span forOutputCustom I/O RangesAdjustable OutputTest/OverrideFunctionTerminals forRemote OutputTest/OverrideSink or SourcemA InputUniversal Power1 2 3 45 6 7 89 10 11 1213 14 15 16See WiringDiagrams onNext Page© 11-19api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502AABSOLUTEBSOLUTE PPROCESSROCESS IINSTRUMENTSNSTRUMENTSQuick Link: api-usa.com/4300Free FactoryI/O Setup!H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAFile E14596885-265 VAC, 60-300 VDCmodel onlyApplications Linkapi-usa.com/appsPb LeadFree |
Related manuals for Absolute Process Instruments APD 4300
Absolute Process Instruments API 1600 G Manual
Absolute Process Instruments APD 4008 Quick Start Manual
Absolute Process Instruments APD 6380 Quick Start Manual
Absolute Process Instruments APD 2016 Quick Start Manual
Absolute Process Instruments APD 7580 Quick Start Manual
Absolute Process Instruments APD 6010 Quick Start Manual
Absolute Process Instruments APD 7010 Quick Start Manual
Absolute Process Instruments APD 1401 Quick Start Manual
Absolute Process Instruments APD HV-DC Quick Start Manual
Absolute Process Instruments APD 44 Series Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved