Absolute Process Instruments APD 6380 Quick Start Manual
AC to DC Transmitters, Isolated, Field Rangeable APD 6380Input: True RMS 0-40 mVAC to 0-300 VAC, 0-4 mAAC to 0-200 mAACOutput: 0-1 V to 0-10 VDC, ±5 VDC, ±10 VDC, 0-2 mA to 20 mADCO One Minute Setup for Hundreds of I/O RangesO External Switches & Tables for Range SelectionO Zero and Span Output Calibration PotentiometersO Full 1200 V Input/Output/Power IsolationO Input and Output LoopTracker®LEDsO Output Test ButtonO Built-In Loop Power Supply for Sink/Source OutputQ Convert, Boost, and Rescale Process SignalsQ Isolate Single-Ended (Common Ground) PLC InputsQ Interface Process Signals with Panel Meters, PLCs,Recorders, Data Acquisition, DCS, & SCADA SystemsApplicationsOptions–add to end of model numberM01 Output reversal, such as 20-4 mA outputU Conformal coating for moisture resistanceAccessory—order as separate line itemAPI BP4 Spare removable 4 terminal plug, blackModel Input Output PowerAPD 6380 Field configurable—specify range iffactory is to set switchesField configurable—specify range iffactory is to set switches85-265 VAC or 60-300 VDCAPD 6380 D 9-30 VDC or 10-32 VACDescriptionThe APD 6380 accepts an AC voltage or current input andprovides an optically isolated DC voltage or current output thatis linearly related to the input.Typical applications include signal isolation, conversion, boost-ing or a combination of the three. Full 3-way isolation (input,output, power) makes this module useful for ground loopelimination, common mode signal rejection or noise pickupreduction.Sink/Source Output VersatilityFor maximum versatility a milliamp output can be selectivelywired for sinking or sourcing. This allows the APD 6380 mil-liamp output to connect to a powered or unpowered currentloop. The 20 VDC output loop supply can be used to power apassive mA device if required.LoopTrackerAPI exclusive features include two LoopTracker LEDs (green forinput, red for output) that vary in intensity with changes in theprocess input and output signals. These provide a quick visualpicture of your process loop at all times and can greatly aid insaving time during initial startup and/or troubleshooting.Output TestAn API exclusive feature includes the test button to provide afixed output (independent of the input) when held depressed.The test output level is potentiometer adjustable from 0 to100% of output span.The output test button greatly aids in saving time during initialstartup and/or troubleshooting.All models are field rangeableFor APD 6380, specify if UL version is requiredOrder options and accessories as requiredOrder D versions for operation on low voltage powerHow to OrderFree factory setup. Please specify on your orderInput rangeOutput rangeAC Input RangesField selectable ranges via switch settingsVoltage: 0-40 mVAC to 0-300 VACCurrent: 0-4 mAAC to 0-200 mAACMeasurements are true RMSInput ImpedanceVoltage (0-4 VAC): 1 MΩ minimumVoltage (>4 VAC): 220 kΩ minimumCurrent: 10 Ω typicalInput Frequency40 Hz to 1000 Hz sinusoidalCommon Mode Rejection120 dB minimumLoopTrackerVariable brightness LEDs indicate I/O loop level and statusDC Output RangesField selectable ranges via switch settingsVoltage: 0-1 VDC to 0-10 VDC, 10 mA maxBipolar voltage: ±1 VDC to ±10 VDCCurrent: 0-2 mADC to 0-20 mADC20 V compliance, 1000 Ω at 20 mAOutput offset: ±100% in 15% incrementsOutput CalibrationMulti-turn zero and span potentiometers±15% of span adjustment range typicalOutput Loop Power Supply20 VDC nominal, regulated, 25 mADCMax. ripple, less than 10 mVRMSMay be selectively wired for sinking or sourcing mA outputOutput TestFront momentary button sets output to test levelPotentiometer adjustable 0-100% of spanOutput Ripple and NoiseLess than 10 mVRMS ripple and noiseLinearityBetter than ±0.1% of spanAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than ±0.02% of span per °C stabilityResponse Time200 milliseconds nominal (0-90%)Isolation1200 VRMS minimumFull isolation: power to input, power to output, input to outputPower85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximumD versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximumHousing and ConnectorsIP 40, requires installation in panel or enclosureFor use in Pollution Degree 2 EnvironmentMount vertically to a 35 mm DIN railFour 4-terminal removable connectors, 14 AWG max wire sizeDimensions0.89" W x 4.62" H x 4.81" D22.5 mm W x 117 mm H x 122 mm DHeight includes connectorsConnect mA Outputfor Sink or SourceOutput LoopTrackerLEDInput LoopTrackerLEDAdjustable OutputTest FunctionHundreds of RangeSelectionsAdjustable OutputOffsetUniversalPowerZero and Span forOutputRemovable Plugs© 11-19api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502AABSOLUTEBSOLUTE PPROCESSROCESS IINSTRUMENTSNSTRUMENTS1 2 3 45 6 7 89 10 11 1213 14 15 16See WiringDiagrams onPage 3Quick Link: api-usa.com/6380MinuteSetup!1Free FactoryI/O Setup!H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAFile E14596885-265 VAC, 60-300 VDCmodel onlyApplications Linkapi-usa.com/appsPb LeadFree |
Related manuals for Absolute Process Instruments APD 6380
Absolute Process Instruments APD 6010 Quick Start Manual
Absolute Process Instruments APD 7580 Quick Start Manual
Absolute Process Instruments APD 7010 Quick Start Manual
Absolute Process Instruments APD 4008 Quick Start Manual
Absolute Process Instruments APD 2016 Quick Start Manual
Absolute Process Instruments APD 1401 Quick Start Manual
Absolute Process Instruments APD HV-DC Quick Start Manual
Absolute Process Instruments API 6380 G Series Quick Start Manual
Absolute Process Instruments APD 44 Series Quick Start Manual
Absolute Process Instruments API 6380 G HV Series Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved