Absolute Process Instruments APD HV-DC Quick Start Manual
High Voltage DC to DC Transmitters, Isolated, Field Rangeable APD HV-DCInput: 0-100 VDC to 0-1200 VDCOutput: 0-1 V to ±10 VDC or 0-2 mA to 4-20 mAO Field Selectable I/O RangesO Zero and Span Output Calibration PotentiometersO Full 1200 V Input/Output/Power IsolationO Input and Output LoopTracker® LEDsO Output Test ButtonO Selectable Sink/Source for Current OutputApplicationsOptions–add to end of model numberC Custom range, >1200 VDC to 2000 VDC max.U Conformal coating for moisture resistanceAccessory—order as separate line itemAPI PB4 Spare removable plug, black 4 terminalModel Input Output PowerAPD HV-DC 8 field selectable ranges1 custom input range can bespecified if required18 field selectable ranges 85-265 VAC or 60-300 VDCAPD HV-DC D 9-30 VDC or 10-32 VACFunctionThe APD HV-DC accepts a DC voltage input and provides anoptically isolated DC voltage or current output that is linearlyrelated to the input. This module is unique because it is fieldrangeable for voltage inputs from 100 VDC to 1200 VDC.Typical applications include signal isolation and signal conver-sion for a high voltage DC input.IsolationThe optical isolation between input and output makes thismodule useful for ground loop elimination, common modesignal rejection or noise pickup reduction. The module powersupply is isolated, resulting in full 3-way (input, output, power)isolation.Fast Field SetupThe APD HV-DC input and output range settings can be recon-figured in the field via external switches. Range settings areon the module label. A user specified range is available thatcan be factory configured to meet your specific requirements.Consult the factory for assistance.Sink/Source OutputFor maximum versatility the output can be selectively wired forsinking or sourcing. The built-in 20 VDC loop excitation supplymay be used to power passive mA devices. This allows the APDHV-DC to work with powered or unpowered mA devices.LoopTrackerAPI exclusive features include two LoopTracker LEDs (green forinput, red for output) that vary in intensity with changes in theprocess input and output signals. These provide a quick visualpicture of your process loop at all times and can greatly aid insaving time during initial startup and/or troubleshooting.Output TestAn API exclusive feature includes a test button to provide afixed output (independent of the input) when held depressed.The test output level is potentiometer adjustable from 0 to100% of output span.The output test button greatly aids in saving time during initialstartup and/or troubleshooting.All models are field rangeableFree factory setup and calibrationThe APD HV-DC has a custom input range than can be factoryset to your specifications at no extra costHow to OrderPlease specifyModelInput range (if you would like us to set the switches)Output range (if you would like us to set the switches)Custom range, if requiredOption as requiredInput Ranges8 field selectable ranges0-100 VDC0-200 VDC0-300 VDC0-400 VDC0-500 VDC0-1000 VDC0-1200 VDCCustom range—consult factory, 2000 VDC max.Input Impedance (Voltage)2.5 MΩCommon Mode Rejection120 dB minimumLoopTrackerVariable brightness LEDs indicate I/O loop level and statusOutput Ranges18 field selectable rangesVoltage: 0-1 V, 0-2 V, 0-4 V, 0-5 V, 1-5 V, 0-8 V,0-10 V, 2-10 VBipolar voltage: ±5 V, ±10 VCurrent: 0-2 mA, 0-4 mA, 0-8 mA, 0-10 mA,2-10 mA, 0-16 mA, 0-20 mA, 4-20 mA20 V compliance, 1000 Ω at 20 mAConsult factory for special rangesOutput CalibrationMulti-turn zero and span potentiometers to compensate forload and lead variations±15% of span adjustment range typicalOutput Loop Power Supply20 VDC nominal, regulated, 25 mADC, max. ripple <10 mVRMSMay be selectively wired for sinking or sourcing mA outputOutput TestFront button sets output to test level when pressedPotentiometer adjustable 0-100% of spanOutput Ripple and NoiseLess than 10 mVRMS ripple and noiseLinearityBetter than ±0.1% of spanAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than ±0.04% of span per °C stabilityResponse Time100 milliseconds nominalIsolation1200 VRMS minimumFull isolation: power to input, power to output, input to outputPower85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximumD versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximumHousing and ConnectorsIP 40, requires installation in panel or enclosureMount vertically to a 35 mm DIN railFour 4-terminal removable connectors, 14 AWG max wire sizeDimensions0.89" W x 4.62" H x 4.81" D22.5 mm W x 117 mm H x 122 mm DHeight includes connectorsUniversalPowerRemovable PlugsSink or SourcemA OutputOutput LoopTrackerLEDInput LoopTrackerLEDZero and Span forOutputCustom I/O RangesAdjustable OutputTest/OverrideFunctionHigh VoltageDC InputQ High Voltage Battery SystemsQ DC Motor and Variable Speed DrivesQ Electric Railway VoltagesQ Power Supply and Voltage Converters1 2 3 45 6 7 89 10 11 1213 14 15 16See WiringDiagrams onNext Page© 07-20api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502AABSOLUTEBSOLUTE PPROCESSROCESS IINSTRUMENTSNSTRUMENTSQuick Link: api-usa.com/HVDCMinuteSetup!1Free FactoryI/O Setup!H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAApplications Linkapi-usa.com/appsPb LeadFree |
Related manuals for Absolute Process Instruments APD HV-DC
Absolute Process Instruments APD 1401 Quick Start Manual
Absolute Process Instruments APD 2016 Quick Start Manual
Absolute Process Instruments APD 6380 Quick Start Manual
Absolute Process Instruments APD 4008 Quick Start Manual
Absolute Process Instruments APD 6010 Quick Start Manual
Absolute Process Instruments APD 7580 Quick Start Manual
Absolute Process Instruments APD 7010 Quick Start Manual
Absolute Process Instruments APD 44 Series Quick Start Manual
Absolute Process Instruments APD 44H Series Quick Start Manual
Absolute Process Instruments AP11400 G Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved