Parameter Settings DescriptionV Blanking Off Disables blanking of the vertical interval.OnOn Enables blanking of the vertical interval.Analog Ref Off External analog reference disabled.On External analog reference enabled.V Phase Numeric Adjusts vertical output video phase. Rangeis ± 8 lines.H Phase Numeric Horizontal output video phase inapproximately 37 ns steps (1/2 pixel clockrate). Range is -858 to +857.Fine H Phase Numeric Fine horizontal output video phase timingin approximately 4.6 ns steps. Range is from-4 to +3.Clips Off Hides Clip menu in GUI and when scrollingthrough menus with the Control Panel.On Enables Clip menu in GUI and whenscrolling through menus with the ControlPanel.Auto Enables clips to be defined with eachrecording.VITC line 1 10 - 20 Allows placement of the first line of VITCon Diskus’ output on any line between 10and 20 inclusive. The default setting is line12.Engineering Menus Diskus Technical Guide7-38 Installation 9100-0217-02 - SEP 95