Document 50934 Rev B 5/15/00 PN 50934:B12If the control panel causes harm to the telephone network, the telephone companyreserves the right to temporarily discontinue service. Advance notification will beprovided except in cases when advance notice is not practical. In such cases,notification will be provided as soon as possible. The opportunity will be given tocorrect any problems and to file a complaint.DO NOT CONNECT THIS PRODUCT TO COIN TELEPHONE, GROUND START,OR PARTY LINE SERVICES.When the control panel activates, premise phones will be disconnected.Two separate phone lines are required. Do not connect both telephone interfaces tothe same telephone line.The control panel must be connected to the public switched telephone networkupstream of any private telephone system at the protected premises.An FCC compliant telephone cord must be used with this equipment. This equipmentis designed to be connected to the telephone network or premises wiring using acompatible RJ31X male modular plug which is Part 68 compliant.1.9.1 Normal Mode:Normal mode is the standard mode of operation. In this mode, the ADT-UDACTmonitors host FACP status as well as monitoring telephone line voltage. The ADT-UDACT reports system status information to UL listed Central Stations. Informationtransmitted includes general alarm, trouble and supervisory. It also transmits eitherthe number of zones or points activated or the specific point(s) activated, dependingupon the compatible panel, programming selections and transmission formatselection. Specific system trouble conditions and specific ADT-UDACT troubles arealso transmitted.1.9.2 Program Mode:Program mode is used to program the ADT-UDACT. While the ADT-UDACT is inthe program mode, it cannot receive host FACP status information. See Section 3.0for complete programming instructions.1.9.3 Lamp Test Mode:This mode turns on all segments of the 4 character display plus all LEDs on the ADT-UDACT.1.9.4 Troubleshoot Mode:Troubleshoot mode may be used for testing the telephone line wiring. Connectionfrom the ADT-UDACT's modular jacks, through RJ31X jacks and into the telephonenetwork may be easily checked. In this mode, the keypad acts similar to a telephonetouchpad.1.9.5 Type Mode:Type Mode is used to define the specific type of device (point) used or function of azone. Type Mode is also used to disable the alarm report for any zone/point in thesystem. The feature which disables the zone/point alarm report must be used forzones/points programmed into the host FACP as remote silence, reset, drill oracknowledge switches. Note: Unimode2020/1010 and ADT-MNNA applicationsrestrict Type Mode programming to a maximum of 568 points. All remaining pointsabove 568 will report as fire alarm points only.1.9 Modes andSpecial Functions