VISTA-128BP/VISTA-250BP Installation and Setup Guide4-10Using an RF Transmitter ZoneA button type RF transmitter (5804) can be used toprovide access or egress for up to 4 doors. One buttonwill control one door. Also, a button can be used toprovide access or egress due to a panic or duresscondition.An RF transmitter (5816) can be used with a remoteswitch to provide exit in case of a fire alarm using aPassPoint event action. To program the RF transmitterfor access control, perform the following steps:Step Action1 Enter Zone Programming in the #93 MenuMode.2 Program the zone with a response type 27(Access Point).3 Enter the access point number (00-31) of thedoor.4 Indicate whether RF device is for entry or exit.5 Enter the partition number6 Enter the input type: button RF (05).7 Enter the loop number.8 Enroll the serial numberSee Zone Programming in the Programming Guide for adetailed explanation.• RF buttons and pendants must be assignedto a user number in order to function. SeeSECTION 9: User Access Codes for theprocedure.• An RF transmitter will not provide access orgrant if the system is in any test mode.Using Wireless KeypadsWireless keypads (5827 & 5827BD) can provide anotherway of entering or exiting the premises. They functionthe same as alpha keypads, except when the code + #73 is entered. This entry will allow momentary accessto ALL access points in the partition to which thekeypad is assigned To program the wireless keypad,enter the partition the keypad is assigned to in field1*48.Control of Lighting and AppliancesLighting and appliances can be controlled when anaccess or exit event occurs. Lights or appliances can beautomatically turned on or off when a valid entry oregress request is presented at an access point. Tocontrol these devices, the VISTA-128BP/VISTA-250BPrelays or the ACS relays or triggers are used withkeypads and/or RF transmitters whose response type isAccess Point (27).To program the control of lighting and appliances,perform the following steps:Step Action1 Enter Output Programming in the #93 MenuMode.2 Program all the information for the relay.3 Select the output type: ECP (1) (4204/4204CF)or (2) (X-10).See Output Programming in the Programming Guidefor a detailed explanation.Using the VISTA-128BP/VISTA-250BP for Stand-Alone Access ControlThe VISTA-128BP/VISTA-250BP can be used for accesscontrol without interfacing to PassPoint ACS orVistaKey. A user can trigger an access point (i.e., doorstrike) for 2 seconds by entering User Code + [0].To program the VISTA-128BP/VISTA-250BP for Stand-Alone access control, perform the following steps:Step Action1 Enter Output Programming in the #93 MenuMode.2 Program the output type as 1, or 2.3 For type 1, program the ECP address andrelay number.4 For type 2, program the house and unit codes.5 Program the relay number in field 1∗76(partition-specific).See Output Programming in the Programming Guidefor a detailed explanation.Programming for ECP Long Range Radio Programming for the Event Log• Program the LRR in Device Programming in the#93 Menu Mode Programming.• Field ✳56: Selects the time the panel should waitbefore it attempts to send a message to the seconddestination..• Field ✳57: Select the initial reporting destinationfor messages.• Field ✳58: Select events for the primary sub’s ID• Field ✳59: Select events for the secondary sub’s ID.• 1✳70 Event Log Types (1=enable; 0=disable foreach type)• 1✳71 12/24-Hour Time Stamp Format (0=12 hr;1=24 hr)• 1✳72 Event Log Printer On-line (0=disable;1=enable)• 1✳73 Printer Baud Rate (1=300; 0=1200)• Event Log Report Codes System Group #2 in the#93 Menu Mode.