– 7 –6<67(029(59,(:About the Display and IndicatorsDisplay Definitions (for other displays, seeTrouble Messages on page 27)ALARM: Appears when an intrusion hasbeen detected and the system isarmed (also appears during a firealarm or audible emergencyalarm). Accompanied by theprotection zone in alarm.AWAY: All burglary zones, interior andperimeter, are armed.ALARMAWAYINSTANTSTAYFIREREC MESSAGEBYPASS FAULTCHIME TESTLOW BAT ACINSTANT: Entry delay is turned off.STAY: Perimeter burglary zones, such as protected windows and doors, arearmed.FIRE: Appears when a fire alarm or fire fault is present. Accompanied by adisplay of the zone in alarm.LOW BAT: Low battery condition in a wireless sensor (if zone number is displayed)or low system battery (if no zone number is displayed). If 00 isdisplayed, a wireless keypad (5827/5827BD) has a low batterycondition.AC: Appears when AC power is present. If not lit, the system is operating onbackup battery power.CHIME: Appears when the Chime feature is activated.TEST: Appears when the system is in Test mode.REC: Appears when in Recording mode.MESSAGE: Appears when a message has been recorded and has not yet beenplayed back.BYPASS: One or more burglary protection zones have been bypassed.FAULT: Appears when a malfunction is discovered in the system at any time;or if an open is detected in a fire zone at any time; or when a fault in aday/night burglary zone is discovered during a disarmed period.Accompanied by a display of the zone number in trouble.LED MeaningsARMED (Red) LED: ON = System armedOFF = System disarmedBlinking = System armed, but a fault existsREADY (Green) LED: ON = System disarmed, ready to armBlinking = System disarmed, not ready to arm (a fault exists)NOTE: When the system is armed, the READY LED turns off.