N8889QSV2 6/99®/<1;/<1;54XLN6WDUW*XLGH8/ LYNX-R is not intended for UL985 Household Fire applications.IntroductionThis Quick Start Guide can help you install the LYNX (non-rechargeable) and LYNX-R(rechargeable ) quickly and easily by providing the basic steps for installation using the built-indefaults. For more detailed information and important notes, refer to the LYNX and LYNX-RInstallation Instructions.The following steps assume that one of the system’s default tables will be used.For programming data values and Powerline Carrier Devices other than those listed in the defaulttables, see the Installation Instructions.Default Table SummaryZone Table 1 Table 2 Table 3 Table 41 ------- ------- ------- -------2 front door front door front door front door3 back door back door back door back door4 window Garage door window window5 motion detector motion detector window window6 ------- smoke detector window window7 ------- ------- window window8 ------- ------- motion detector motion detector9 ------- ------- smoke detector smoke detector26 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away27 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm28 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device29 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 130 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device33 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 192 duress duress duress duress99 silent alarm silent alarm silent alarm silent alarmUserCode 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4InstallCode 4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2Entering Program Mode: installer code + 8 0 0Interactive Mode Used to Program*56 Enhanced Zone Programming Zone characteristics, report codes, and serial numbers*83 Sequential Mode 5800 Series transmitter serial numbers*84 Assign Zone Voice Descriptors Voice descriptors for each zoneExiting Program Mode: *99 allows re-entry into the Program mode using Installer Code + 8 0 0.*98 inhibits re-entry into the Programming mode using the Installer Code.NOTES: • Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phonenumber),and a Powerline Carrier Device programmed as device 8, which closes and stays closedupon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using apulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.• Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use ContactID for secondary reporting. Tables 1, and 3 use 4+1 format for secondary reporting.• Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores,troubles, and trouble restores in their event logs.