2 Installation2.1.1 Servomotor Installation Environment2-22.1 Installation Environment and Applicable StandardsThe installation environment and the applicable standards for servomotors andSERVOPACKs are described in this section.2.1.1 Servomotor Installation Environment Ambient temperature: 0 to 40°C Ambient humidity: 80% RH or less (with no condensation) Altitude: 1, 000 m or less Vibration resistance Shock resistance: 490 m/s2 at servomotor flange Installation site: An environment that satisfies the following conditions• Indoors and free of corrosive or explosive gases• Well-ventilated and free of dust and moisture• Facilitates inspection and cleaning• Free of high magnetic fieldThe servomotor will withstand the followingvibration acceleration in three directions: vertical,side to side, and front to back.Servomotor Model Vibration Accelerationat FlangeSGMJV, SGMAV, SGMPS,SGMCS-02 to -35 49 m/s 2SGMGV-03 to -44,SGMSV-10 to -5049 m/s 2(Front to back direction:24.5m/s 2)SGMGV-55 to -1E,SGMCS-45 to -2Z 24.5 m/s 2SGMSV-70 14.7 m/s 2HorizontalImpact Applied to theServomotorVerticalFront toBackSide to Side