6-38 Phaser 3635MFPdC305, dC330Draft 4General Procedures and InformationdC305 UI TestPurposeTo initiate component testing of the local UI. This function also provides a means to test the UImemory and to restart the local UI.DescriptionRefer to GP 12 User Interface Tests Description.Procedure1. Enter diagnostics, GP 1.2. Select, Diagnostics Routines, Copier Routines, dC305 UI Tests.3. Touch the appropriate test button.4. Touch Start Test and follow the on-screen instructions.dC330 Component ControlPurposeTo show the status of input components e.g. sensors, and to energize output components e.g.motors, solenoids.DescriptionOutput and input component codes are entered into the Component Control Table on the UI,and then energized individually or in permitted groups. The codes in the tables are grouped insimilar functional behaviour.Go to the appropriate procedure:• Input Components• Output ComponentsInput ComponentsWhen the appropriate code is entered the status of the component will be shown on the UI.NOTE: The actual signal as measured with a service meter will not necessarily be the same asthe logic state shown on the UI, especially where the output is inverted. When testing compo-nents using these control codes, look for a change in state, not for a high or low.The displayed status of the input component can be changed by causing the component statusto change, e.g. operating a sensor with a sheet of paper. When a sensor is operated a beepwill sound.Go to the appropriate table:• Table 1 Input Codes 01• Table 2 Input Codes 05• Table 3 Input Codes 06• Table 4 Input Codes 07• Table 5 Input Codes 08• Table 6 Input Codes 09• Table 7 Input Codes 10Output ComponentsWhen the appropriate code is entered, the component will energize for a set time and then stopin order to protect the components. The default time-out for all components is shown. Somecomponents require that other components are energized at the same time and it is possible toenter and energize up to six component control codes (not fax), but only in permitted groups. Ifillegal combination of codes are entered the illegal codes will not energize.Go to the appropriate table:• Table 8 Output Codes 04• Table 9 Output Codes 05• Table 10 Output Codes 06• Table 11 Output Codes 08• Table 12 Output Codes 09• Table 13 Output Codes 10• Table 14 Output Codes 20