TOBY-R2 series - System integration manualUBX-16010572 - R10 Approvals Page 132 of 151☞ In order to use the module as a T-Mobile certified device, the +UIMSCFG AT command shall beused to turn off VoLTE functionality: cellular capabilities of the device are not modified (to keepconsistence with the PICS), but the UE will not be allowed to receive MT calls nor to perform MOnormal or emergency calls. The CSFB feature is disabled with appropriate setting of LTE operationmode via AT+CEMODE=2 command. For more details about the mentioned AT commands, seeu-blox AT commands manual [2].4.2 US Federal Communications Commission noticeUnited States Federal Communications Commission (FCC) IDs: u-blox TOBY-R200 cellular modules: XPY1EHM44NN u-blox TOBY-R202 cellular modules: XPY1EHQ24NN4.2.1 Safety warnings review the structure Equipment for building-in. The requirements for fire enclosure must be evaluated in the endproduct The clearance and creepage current distances required by the end product must be withheld whenthe module is installed The cooling of the end product shall not negatively be influenced by the installation of the module Excessive sound pressure from earphones and headphones can cause hearing loss No natural rubbers, hygroscopic materials, or materials containing asbestos are employed4.2.2 Declaration of ConformityThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: this device may not cause harmful interference this device must accept any interference received, including interference that may causeundesired operation⚠ Radiofrequency radiation exposure Information: this equipment complies with radiation exposurelimits prescribed for an uncontrolled environment for fixed and mobile use conditions. Thisequipment should be installed and operated with a minimum distance of 20 cm between theradiator and the body of the user or nearby persons. This transmitter must not be co-located oroperating in conjunction with any other antenna or transmitter except as authorized in thecertification of the product.⚠ The gain of the system antenna(s) used for the TOBY-R2 series modules (i.e. the combinedtransmission line, connector, cable losses and radiating element gain) must not exceed the valuespecified in the FCC Grant for mobile and fixed or mobile operating configurations:o TOBY-R200 modules: 9.8 dBi in 700 MHz, i.e. LTE FDD-12 band 4.0 dBi in 850 MHz, i.e. GSM 850, UMTS FDD-5 or LTE FDD-5 band 7.8 dBi in 1700 MHz, i.e. LTE FDD-4 band 2.2 dBi in 1900 MHz, i.e. GSM 1900, UMTS FDD-2 or LTE FDD-2 bando TOBY-R202 modules: 9.7 dBi in 700 MHz, i.e. LTE FDD-12 band 10.0 dBi in 850 MHz, i.e. UMTS FDD-5 or LTE FDD-5 band 7.9 dBi in 1700 MHz, i.e. LTE FDD-4 band 8.5 dBi in 1900 MHz, i.e. UMTS FDD-2 or LTE FDD-2 band