December 2005 © TOSHIBA TEC e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE2 - 472520 Fuser Fuser roller temperatureduring printing(Center thermistor/Enve-lope)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1521 Fuser Fuser roller temperatureduring printing(Side thermistor/Envelope)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1523 Fuser Pre-running time for firstprinting(Envelope)ALL 10<0-15>M 0: Invalid 1: 1 sec.2: 2 sec. 3: 3 sec.4: 4 sec. 5: 5 sec.6: 6 sec. 7: 7 sec.8: 8 sec. 9: 9 sec.10: 10 sec.11: 12 sec.12: 14 sec.13: 16 sec.14: 18 sec.15: 20 sec.1525-0 Fuser Temperaturedrop switchingtime settingduring printing(Center ther-mistor)The firstdropALL 20<0-200>M This code is valid onlywhen “20” is set to 08-535.Setting value x 5 sec.:from 0 to 1,000 sec.later4525-1 The sec-ond dropALL 38<0-200>M 4525-2 The thirddropALL 75<0-200>M 4525-3 The fourthdropALL 75<0-200>M 4526 Fuser Pre-running time for firstprinting (OHP film)ALL 0<0-15>M 0: Invalid 1: 0 sec.2: 2 sec. 3: 3 sec.4: 4 sec. 5: 5 sec.6: 6 sec. 7: 7 sec.8: 8 sec. 9: 9 sec.10: 10 sec.11: 12 sec.12: 14 sec.13: 16 sec.14: 18 sec.15: 20 sec.1527-0 Fuser Temperaturedrop switchingtime settingduring printing(Side ther-mistor)The firstdropALL 20<0-200>M This code is valid onlywhen “20” is set to 08-535.Setting value x 5 sec.:from 0 to 1,000 sec.later4527-1 The sec-ond dropALL 30<0-200>M 4527-2 The thirddropALL 48<0-200>M 4527-3 The fourthdropALL 75<0-200>M 4Setting mode (08)Code Classifi-cation Items Func-tionDefaultablevalue>RAM Contents Proce-dure PreviousNext |