e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE December 2005 © TOSHIBA TEC2 - 40386 Counter Counter for Platen ALL 0<6 digits>M Counts the number oforiginals fed from platen2388 Counter Copying total counter /MAIN board SRAMboardALL - - Copies the total countervalue of the MAINboard to the SRAMboard.15389 Counter Copying total counter /SRAM board MAINboardALL - - Copies the total countervalue of the SRAMboard to the MAINboard.15400 Fuser Fuser unit error statuscounterALL 0<0-19>M 0: No error1: C41 (Once)2: C41 (consecutivelyoccurred)3: C46 4: C435: C44 6: C457: C44 8: C459: C44 10: C4711: C47 12: C4813: C49 14: C4715: C48 16: C4917: C47 18: C4819: C491404-0 Fuser Temperaturedrop setting inready status(Center ther-mistor)The firstdropALL 1<0-10>M This code is valid onlywhen “20” is set to 08-886.Setting value x -5°C:from 0°C to -50°C4404-1 The sec-ond dropALL 1<0-10>M 4404-2 The thirddropALL 1<0-10>M 4404-3 The fourthdropALL 1<0-10>M 4405-0 Fuser Temperaturedrop setting inready status(Side ther-mistor)The firstdropALL 3<0-10>M 4405-1 The sec-ond dropALL 3<0-10>M 4405-2 The thirddropALL 3<0-10>M 4405-3 The fourthdropALL 3<0-10>M 4407 Fuser Fuser roller temperature inready status(Side thermistor)ALL 6<0-12>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C1409 Fuser Fuser roller temperature atenergy saver mode(Center thermistor)ALL 0<0-13>M 0: OFF 1: 40°C2: 50°C 3: 60°C4: 70°C 5: 80°C6: 90°C 7: 100°C8: 110°C 9: 120°C10: 130°C11: 140°C12: 150°C13: 160°C1Setting mode (08)Code Classifi-cation Items Func-tionDefaultablevalue>RAM Contents Proce-dure06/05 PreviousNext |