– 85 –– 5 –5 InstallationWARNINGInstall the air conditioner certainly to sufficiently withstand the weight.If the strength is insufficient, the unit may fall down resulting in human injury.Perform a specified installation work to guard against strong wind or earthquake.An incomplete installation can cause accidents by the units falling and dropping.REQUIREMENTStrictly comply with the following rules to prevent damage of the indoor units and human injury.• Do not put a heavy article on the indoor unit. (Even units are packaged)• Carry in the indoor unit as it is packaged if possible.If carrying in the indoor unit unpacked by necessity, be sure to use buffering cloth, etc. to not damage the unit.• To move the indoor unit, hold the hooking metals (4 positions) only.Do not apply force to the other parts (refrigerant pipe, drain pan, foamed parts, or resin parts, etc.).• Carry the package by two or more persons, and do not bundle it with PP band at positions other than specified.• Use a forklift to transport materials. Do not drag or push the package because it is made of cardboard.• If the vibration insulator is applied to the hanging bolt, make sure it does not cause larger vibration in the main unitbefore using it. External viewInstalling the four 3/8" (M10)-diameter hanging bolts• Space the hanging bolts according to the dimensions shown in the diagrams below.• Use 3/8" (M10)-diameter hanging bolts (Required at the site).Unit: in (mm)Considering piping and wire connecting works in the ceiling after hanging down the indoor unit, select aninstallation place and then determine the drawing-out direction of the pipes.• If the ceiling has been already set, draw the refrigerant pipe, drain pipe, inter-unit wire between indoor andoutdoor units, central control system wire and remote control cord up to the positions where pipes and wires areconnected before hanging down the indoor unit.Model MMD- A B C DAP048∗ 35.4" (898) 32.2" (818) Ø3/8" (9.5) flare Ø5/8" (15.9) flareAP072∗AP096∗ 55" (1398) 49.6" (1260) Ø1/2" (12.7) flare Ø7/8" (22.2) brazingB(Hanging bolt pitch)4-M0.4" (10) hangingbolt (Locally procured)50.7" (1288) (Hanging bolt pitch) ElectricalcontrolboxA3.4" (87)52.3" (1328)Refrigerant pipe connecting port(Liquid side) CDrain pipe connecting portRefrigerant pipe connecting port(Gas side) D19.5" (496)2.6"(66)8.6"(218)5.9"(150)1.9"(49)49.8" (1266)0.7" (18)2.4" (60)27.5" (699)33.3"(845) Treatment of ceilingThe ceiling differs according to structure of building.For details, consult your constructor or interior finish contractor.In the process after the ceiling board has been removed, it is important to reinforce ceiling foundation (frame) andto keep horizontal level of installed ceiling correctly in order to prevent vibration of ceiling board. Installation of hanging boltUse 3/8" (M10) hanging bolts (4 pcs, locally procured).Matching to the existing structure, set pitch according to size in the unit external view as shown below. Hanging up of unit• Adjust the nut position (lower side).• Hang up the main unit by hanging nut of hanging bolt to T groove of hanging bracket of the indoor unit.• Using the level vial, etc., check that four sides are horizontal. (Horizontal degree: within 0.2" (5 mm))• Attach canvas ducts (locally procured) to the air intake and the air discharge so that vibration of the main unitdoes not travel to the duct or ceiling. Attach also acoustic-absorption material to the inner liner of the duct andthe vibration-proof rubber to the hanging bolt.REQUIREMENT• Using a level vial, etc., confirm the horizontal level of the indoor unit.• Tighten the nut sufficiently, and fix it securely.New concrete slab Steel flame structure Existing concrete slabInstall the bolts with insert brackets or anchorbolts.Use existing angles or install newsupport angles.Use a hole-in anchors, hole-inplugs, or a hole-in bolts.ReinforcingsteelAnchor bolt(Blade typebracket)(Slide typebracket) (Pipe hanginganchor bolt)Hanging boltHanging bolt Support angleHanging bracketHeat insulator(Accessory)* Note that the widths of theAP048, AP072 and AP096models are different.Heat insulator(Accessory) Hanging bracket9-EN 10-EN |
Related manuals for Toshiba MMD-AP0481HF2UL
Toshiba MMD-AP0481HFE Service Manual
Toshiba MMD-UP0481HFP-UL Service Manual
Toshiba MMD- AP0724H2UL Service Manual
Toshiba MMD-AP0724H2UL Service Manual
Toshiba MMD-AP0481HF2UL Owner's Manual
Toshiba MMD-AP0076BHPUL Service Manual
Toshiba MMD-AP0726HP-UL Service Manual
Toshiba MMW-AP0481CHQ-E Service Manual
Toshiba MML-AP0074H2UL Service Manual
Toshiba MMD-AP0726HP-E Service Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved