6-81DNW-A100/A50/A45DNW-A100P/A50P/A45P6-6. SS-63 Board Replacement6-6. SS-63 Board ReplacementFor the board replacement, refer to “6-1-3. Pulling out/Insertion of Plug-in Board”.However, the following service operations are required inbefore and after the SS-63 board replacement.Before replacement. Check the setting of setup menu (Main menu andExtended menu of 525/60 and 625/50 systems)Record the setting of setup menu to a copy of the settingcheck sheet in Appendix B, if possible.. Setting of the DIP switchesSet the DIP switches (S101, S1100, S1102, and S1900)according to the model.Refer to Section 6-6-1 for detail.After replacement. Setting of setup menu (Main menu and Extended menuof 525/60 and 625/50 systems)Reset the setup menu as recorded setting on the settingcheck sheet (copy).. Error logging data clear and Calendar/Clock settingThere is a possibility that the SS-63 board to be installedhas the another error logging data in its NV-RAM.Therefore, clear the error logging data.And, the calendar/clock are required to indicate of theday and time at error occurrence. There is a possibilitythat the date and time are wrong. Set the calendar/clockto the correct day and time.Refer to Section 6-6-2 for detail.nThe NV-RAM on the SS-63 board has the calendar andclock data.S101 This setting is thefactory setting.Ref. No. Setting RemakesONS1100 See below notes.S1900 All OFFOFFONOFFON6-6-1. Setting of DIP Switchesm. The “ ” mark shows the knob position.. For detailed description of each DIP switch, refer toSection 1-10-5.(1) Confirm that the DIP switches S101 (A-1), S1100 (J-1), and S1900 (P-1) are following settings.m. After completing the setting of setup menu, be sure to setthe switch No. 1 of S1100 to identical setting as the SS-63 board that is removed.. Be sure to set the switch No. 2 of S1100 to identicalsetting as the SS-63 board that is removed.(2) Setting the DIP switch S1102 (F-2) as follows:m. Setting is different according to the model.. Numbers of S1102’s switches are different accord-ing to board number suffix. Be sure to confirm thesuffix of board number. The board number is indicat-ed on the left margin (A-6) of side A.DNW-A100Model For suffix-11 and 12 For suffix-13 and higherONOFFONDNW-A50 ONOFFONDNW-A45 ONOFFONDNW-A100P ONOFFONDNW-A50P ONOFFONDNW-A45P ONOFFON