2-15 (E)BKP-50903. Set the menu as follows and adjust the SC-H phaseusing the MENU SELECT knob/switchAdjustment Point:MENU : System configPAGE : Y/Chroma (S2)ITEM : SC-H PhaseSpecification : Position the luminous line of theburst (SC) and the beam spot of Has shown in the figure.(For NTSC)(For PAL)File Store:Execute the file store. Throw the MENU SELECT switchto ENTER twice to execute.MENU : Trimming FilePAGE : Trimming File (T1)ITEM : File StoreRMGCYGY LBR M GCYGY LB2-3-4. INT SC Phase AdjustmentNotes:This adjustment procedures are stated below assuming thatthe Tektronix 1750 (for BVP-500) or 1751 (for BVP-500P)is used.If any other measuring instrument is used, follow theinstructions given in the operation manual attached to it.Equipment : Waveform/Vector monitor(SC-H Phase measuring mode)Test Point : MONITOR connectorPreparations:. Connect the waveform/vector monitor to the MONITORconnector.. S650 (MONITOR SELECT)/IF-538 panel → VBSAdjustment Procedures:1. Set the DISPLAY switch/rear panel from OFF toMENU while pushing up the MENU SELECT switchto ENTER.2. Set the menu as follows.MENU : System configPAGE : Y/Chroma (S2)ITEM : CB → On2-3. Adjustments on BVP-500/500P2-3-4. INT SC Phase Adjustment