Sealey LEd36 Instructions Manual
Also see for LED36: Instructions
IMPORTANT WARRANTY INFORMATION:The battery fitted to this cordless tool is considered to be a consumable item and its ability to accept charge will reduce over time. We willwarranty it against mechanical and electrical defect for a period of one year - this does not cover fair wear and tear. If the battery is notproperly charged before first use, or regularly conditioned, its capacity will diminish. Under these circumstances we will not replace the batteryeven if it is less than one year old.3.1 Make sure the inspection lamp is switched off before commencing charging.3.2 Uncoil the charging lead and plug the connector into the charging socket built into the end of the inspection lamp handle.3.3 Plug the charger into a 230V mains supply.3.4 A small LED in the centre of the lens will illuminate green to indicate that charging is in progress.3.5 The lamp will take 5 hours to fully charge. The LED will go out when charging is complete. Do not continue charging beyond this period.3.6 Unplug the charger from the mains supply. Unplug the charging lead from the inspection lamp.3.7 The inspection lamp will operate continuously for approximately 9 hours on one charge.1. SAFETY2. INTROducTION1.1. GENERAL dO NOT shine directly into your, other person’s or animal’s eyes. dO NOT allow children to use the inspection lamp. dO NOT handle or move the inspection lamp whilst it is being charged. dO NOT use the inspection lamp if you suspect that the battery or the inspection lamp casing is damaged. dO NOT leave battery in a discharged state: recharge battery immediately. If the inspection lamp is not in use, recharge the battery every3 to 4 weeks.1.2. ELEcTRIcAL SAFETY FOR uSE OF cHARGER. USE ONLY THE SUPPLIED CHARGER PLUG FOR CONNECTING INSPECTIONLAMP TO THE POWER SUPPLY. WARNING! It is the user’s responsibility to read, understand and comply with the following electrical instructions:You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual CurrentCircuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD (Residual Current Device) isused with all electrical products, particularly portable equipment which is plugged into an electrical supply not protected by an RCCB.You must also read and understand the instructions concerning electrical safety paragraph 1.2.1 onwards.1.2.1. The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualifiedelectrician, using a Portable Appliance Tester (PAT), at least once a year.1.2.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance andthe safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.1.2.3. You must ensure that you: Inspect the charger plug, cable and connector for wear and damage to ensure items are safe before connecting to the mains powersupply. If worn or damaged dO NOT use. Important: Check that the voltage marked on the charger plug is the same as the power supply to be used. Uncoil the cable between charger and the inspection lamp. dO NOT pull the charger plug from the mains socket by the lead. dO NOT use any other type of charger with this inspection lamp. dO NOT try to take the charger plug apart. dO NOT use the charger plug to charge or power any other electrical item. dO NOT get the charger wet, or use in wet, damp conditions (for indoor use only). WARNING! NEVER substitute a standard 13A 3 pin plug, or any other type of plug, for the charger plug.3. cHARGING4. OPERATIONRobust housing, with rubber grip, incorporating 36 super bright LEDs. Ball joint gripper for easy positioning. Ideal for use in engine bays, under-body inspections and low-light work areas. Supplied with mains charger and LED charging indicator.InSTRUCTIonS foR:cORdLESS 36 LEd REcHARGEABLEINSPEcTION LAMPMoDEL no: LEd36Original Language VersionIMPORTANT: PLEASE REAd THESE INSTRucTIONS cAREFuLLY. NOTE THE SAFE OPERATIONAL REQuIREMENTS, WARNINGS & cAuTIONS. uSE THEPROducT cORREcTLY ANd WITH cARE FOR THE PuRPOSE FOR WHIcH IT IS INTENdEd. FAILuRE TO dO SO MAY cAuSE dAMAGE ANd/OR PERSONALINJuRY ANd WILL INVALIdATE THE WARRANTY. KEEP THESE INSTRucTIONS SAFE FOR FuTuRE uSE.Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,and properly maintained, give you years of trouble free performance.4.1 Mount the lamp to a secure position using the spring loaded gripper. Do not clamp over electrical wiring or onto any rotating components4.2 direct the lens away from your eyes before switching on. Switch the inspection lamp on and off using the red push button switch onthe top of the lamp.IMPORTANT: LED arrays are designed to allow individual LEDs to cease functioning without causing the entire array to fail. This could be as aresult of shock or impact. Shock or impact will invalidate warranty.© Jack Sealey Limited LED36 Issue: 4(SP) - 20/03/14 |
Related manuals for Sealey LED36
Sealey LED36 Instructions Manual
Sealey LED37 Instructions Manual
Sealey LED308 Instructions Manual
Sealey LED3602CF.V2 Instructions Manual
Sealey LED0121R Instructions Manual
Sealey LED3009 Instruction Manual
Sealey LED013 Instruction Manual
Sealey LED033 Instruction Manual
Sealey LED3601.V2 Series Instructions Manual
Sealey LED3601.V3 Series Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved