Ver.CHAPTER 2. Installation of RRH-P42-42 © SAMSUNG Electronics Co., Ltd.2600-00CTEIGAA 4.013) Insert the rain protection filler completely to cable gland body and fasten the cablegland nut by torque 2.17 lbf.ft (30 kgf.cm) using torque wrench. After fixing nut,confirm using the gap gauge that distance between cable gland body and nut is within0.03 in. (1.0 mm).Figure 2.32 Connecting RRH-P4 power cable (AWG8) (6)Power Cable(Hybrid cable, AWG8, 2C)Rain Protection FillerCable Gland NutExternal Power Cable Support BracketPower Cable Outer Jacket(AWG8)Cable Gland NutGap: 0.03 in.Gap GaugeRain Protection Gasket* Insert cable when the unsheathed DC power cable outer jacket locate at the rain protection filterprotrusion.Rain Protection FillerProtrusion