Ver.Smart MBS RRH-P4 Installation Manual/Ver.3.0© SAMSUNG Electronics Co., Ltd. 2-412600-00CTEIGAA 4.010) Insert power terminal protection cap to the installed power cable.11) Align the pressure terminal of the power cable to the power terminal block for properpolarity and fix it with M5 screw.12) After fixing the pressure terminal, cover the power terminal block with power terminalprotection cap.Figure 2.31 Connecting RRH-P4 power cable (AWG8) (5)RTN-48 VHeat Shrink Tube(-48 V: Blue, RTN: Red)Power Terminal Block Fixing ScrewPressure Terminal(Ring Type, Hole diameter: 0.2 in.)Power Terminal Protection CapPower Cable(-48 V: Red, RTN: White/Red strip)