English722. When [LAN control protocol] is setto [Protocol 2].Communicates with he same protocol as that of aPanasonic projector■ When the WEB control administratorprivileges password has been set (Protectmode)Connection method1 Obtain the display’s IP address and the port number(Default is 1024), and request connection to thedisplay.The IP address and the port number can be obtainedfrom the following menus.• IP address:[Setup] → [Network settings] → [LAN setup] or[Network status]• Port number:[Setup] → [Network settings] → [LAN setup]For more detail of the settings, see page 52 - 52.2 The display responds.Response dataData part Space Mode SpaceRandomnumberpartLastterminalsymbol[NTCONTROL](ASCIIcharacterstring)[ ]0x20[1]0x31[ ]0x20[zzzzzzzz](ASCIIcodehexnumber)(CR)0x0d9 bytes 1 byte 1 byte 1 byte 8 bytes 1 byteMode:1 = Protect mode3 Hash the following data with the MD5 algorithm, andgenerate a 32-byte hash value.[xxxxxx:yyyyy:zzzzzzzz]xxxxxx :WEB control administrator privileges user nameyyyyy :Above administrator privileges user password● Default user name and password are as follows:User name: admin1Password: panasoniczzzzzzzz :8-byte random number obtained in step 2Command transmission methodTransmit in the following command formatTransmitted dataHeader Data partLastterminalsymbolHash value(see“Connectionmethod”)‘0’0x30‘0’0x30Controlcommand(ASCIIcharacterstring)(CR)0x0d32 bytes 1 byte 1 byte Undefined 1 byteReceived dataHeader Data partLastterminalsymbol‘0’0x30‘0’0x30Controlcommand(ASCIIcharacterstring)(CR)0x0d1 byte 1 byte Undefined 1 byteError responseError messageLastterminalsymbol“ERR1” : Undefined controlcommand(CR)0x0d“ERR2” : Out of parameter range“ERR3” : Busy status orreception invalid period“ERR4” : Timeout or recep ioninvalid period“ERR5” : Wrong data length“ERRA” : Mismatching ofpassword4 bytes 1 byte