• Is "554" selected for the HTTP port number?For the HTTP port number, select a port number otherthan the following port numbers used by the camera.The number used by the camera: 20, 21, 23, 25, 42,53, 67, 68, 69, 110, 123, 161, 162, 554, 995,10 669, 10 670, 59 000 - 59 999, 60 000 - 61 0007387• Are you accessing the wrong IP address?Check the connection as followsWith the Windows command prompt,> ping "IP address of the camera"If there is reply from the recorder, the connection isnormal.If not, proceed either of the following.• Reboot the camera and change the IP address byusing the Panasonic IP setup software within 20minutes after the restart.• Reboot the camera while holding the [INITIAL SET]button on the camera. The camera will be initializedand the IP address will return to the default setting"192.168.0.10".After the camera is initialized, access the cameraand set the IP address again. (When the camera isinitialized, all the settings of the camera previouslyconfigured on the setup menus will be initialized.)• Is the power of the camera on?Check if the power of the camera is turned on.• Is the LAN cable (category 5 or better) firmly connectedto the network connector of the camera?InstallationGuideInstallationGuide• Are the set IP addresses valid?• Is the link LED lit?When it is not lit, connection to a LAN may not beestablished or a network may be not working correctly.Check if the cables have any contact failure or if thewiring is correct or not.–72TroubleshootingBefore asking for repairs, check the symptoms with the following table.Contact your dealer if a problem cannot be solved even after checking and trying the solution in the table or a prob-lem is not described below.ReferencepagesCause/solutionSymptomCannot access from the webbrowser.InstallationGuide72