646. Move the cross pointer on the screen to the startingpoint for the area by pressing the A, B, D or C but-ton, then press the SET button.7. Move the cross pointer on the screen to the endingpoint for the area by pressing the A, B, D or C but-ton, then press the SET button to determine the rectan-gular detecting area.Four detecting areas can be set on the screen.To assign another detecting area, repeat the abovesteps 6 and 7.8. To delete the area, move the cursor to the rectangle tobe delete on the screen, then press the SETUP/ESCbutton.9. To return to the previous table, press the SETUP/ESCbutton.10. Repeat the above steps 4 to 9 to set the detector func-tion for other cameras.11. Press the SETUP/ESC button to return to the previousALARM SETUP menu.Note: When the detecting area is set small, the functionmay not detect object.It is recommended that the areas and sensitivity lev-els are made test before the settings.1 +AREA SET/ERASE:PRESS[SET] AT CORNER1+AREA SET/ERASE:PRESS[SET] AT CORNER Alarm Mode on the MultiscreenMonitorThis item lets you select the mode for displaying an alarmon the Multiscreen Monitor.1. Move the cursor to the ALARM MODE MULTI OUTPUTin the ALARM SETUP menu by pressing the D or Cbutton.2. Select either SPOT or OFF by pressing the + or - but-ton.SPOT: The camera image that has activated the alarmis displayed in single spot mode.OFF: Ignores alarm activation and continues to displaythe images in the mode selected previously.The factory default setting is SPOT. Alarm Mode on the Spot MonitorThis item lets you select the mode for displaying an alarmon the Spot Monitor.1. Move the cursor to the ALARM MODE SPOT OUTPUT inthe ALARM SETUP menu by pressing the D or C but-ton.2. Select either SPOT or OFF by pressing the + or - but-ton.SPOT: The camera image that has activated the alarmis displayed in single spot mode.OFF: Ignores alarm activation and continues to displaythe images in the mode selected previously.The factory default setting is SPOT.