Panasonic Eco Solutions Nordic ABMEW01623 Rev: - EBL128 Operating Instructions V2.0.x54Output(s) programmed for that fire alarm (alarm point / zone) will bereset, i.e. de-activated.If more than one fire alarm is activated (i.e. LEDs "Alarms queued"(L2) are lit) the next fire alarm in the queue will be shown in thedisplay. It has to be reset the same way as the first one.When all fire alarms are reset, LEDs "Fire" (L1) and "Alarmsqueued" (L2) are turned off. If there are other conditions (e.g. a faultcondition) the corresponding information will be shown (e.g. a faultmessage), for the priority order see chapter "The display in EBL128",page 21.All outputs (for fire alarm) are reset, i.e. de-activated.If a key cabinet is installed, the key (to the building) has to be putback into the key cabinet within 5 minutes. If not, a fault will begenerated and a fault message will be shown in the display, seechapter "Key cabinet alarm reset", page 55.17.2.3 Single with automatic disablementLike "Single reset" but including the so called encapsulation function:Normally when an alarm point or zone having activated fire alarm isreset whilst still is in alarm status, it will activate a new fire alarmwithin 20 seconds. (This is in accordance with the EN54-2 standard.)When "Single with automatic disablement" reset is performed, analarm point or zone, still in alarm status, will not only be reset butalso disabled, i.e. it will not activate a new fire alarm within 20seconds.It has to be re-enabled via menu H2/B6 (see page 92) before it canactivate a new fire alarm. (This function, set via EBLWin, is aviolation to the EN54-2 standard.)LED "Disablements" (L8) is indicating one or more disablements inthe system.NOTE!When "All" or "Single" reset is used, "automatic disablement"(encapsulation function) can be used by pressing "Reset" (P4) andapprox. 0.1 sec. later also press "Alarms queued" (P1) and hold thempressed for > 0.5 sec.The alarm point or the whole zone (conventional) currently shown inthe display will be reset and disabled.17.3 Alert Annunciation alarm resetRegarding the function, see chapter "Alert Annunciation alarm (AAalarm)", page 48 and EBL128 Planning Instructions, chapter "AlertAnnunciation".Reset of the AA alarm can be done via push button "Reset" on an AAunit 1735 / 1736 (an AA controller 1740) or in EBL128. AA alarmswill be reset all at a time.