Troubleshooting 8-7Errorcode Error message Recommended Action8100 Memory Error detected in DIMM group #1.8101 Memory Error detected in DIMM group #2.8102 Memory Error detected in DIMM group #3.8103 Memory Error detected in DIMM group #4.8104 Memory Error detected in DIMM group #5.8105 Memory Error detected in DIMM group #6.Contact your service representative toreplace the DIMM in the relevant group.8160 Mismatch Processor speed detected onProcessor 1.8161 Mismatch Processor speed detected onProcessor 2.Contact your service representative.0B80 BMC Memory Test Failed.0B81 BMC Firmware Code Area CRC check failed.0B82 BMC core Hardware failure.0B83 BMC 1BF or 0BF check failed.Turn off the power once and then on againto start the server. If the error cannot becorrected, contact your servicerepresentative.0B8A BMC SEL area full Clear the system event logs by using theBIOS SETUP utility (see Chapter 4).0B8B BMC progress check timeout.0B8C BMC command access failed.0B8D Could not redirect the console - BMC Busy -0B8E Could not redirect the console - BMC Error -Turn off the power once and then on againto start the server. If the error cannot becorrected, contact your servicerepresentative.0B8F Could not redirect the console - BMCParameter Error -0B90 BMC Platform Information Area corrupted.0B91 BMC update firmware corrupted.Turn off the power once and then on againto start the server. If the error cannot becorrected, contact your servicerepresentative.0B92 Internal Use Area of BMC FRU corrupted. This is not a fatal error. Turn off the poweronce and then on again to restart theserver. If the error cannot be corrected,contact your service representative.0B93 BMC SDR Repository empty. Turn off the power once and then on againto restart the server. If the error cannot becorrected, contact your servicerepresentative.0B94 IPMB signal lines do not respond. This is not a fatal error. Turn off the poweronce and then on again to restart theserver. If the error cannot be corrected,contact your service representative.0B95 BMC FRU device failure. This is not a fatal error. Turn off the poweronce and then on again to restart theserver. If the error cannot be corrected,contact your service representative.0B96 BMC SDR Repository failure.0B97 BMC SEL device failure.0B98 BMC RAM test error.0B99 BMC Fatal hardware error.Turn off the power once and then on againto start the server. If the error cannot becorrected, contact your servicerepresentative.0B9A Management controller not responding. Update the RMC firmware. If the errorcannot be corrected, contact your servicerepresentative.