Installation Instructions Section 22-6 Part Number 80-1560-3WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONSTypical Water Supply Drain Installation! CautionPlumbing must conform to state and local codes.Location Water Temperature Water Pressure Ice Machine Fitting Tubing Size Up to IceMachine FittingIce MakingWater Inlet35°F (1.6°C) Min.90°F (32.2°C) Max.20 psi (137.9 kPA) Min.80 psi (551.5 kPA) Max.3/8" Female PipeThread3/8" (.95 cm) minimuminside diameterIce MakingWater Drain --- --- 1/2" FemalePipe Thread1/2" (1.27 cm) minimuminside diameterCondenserWater Inlet40°F (4.4°C) Min.90°F (32.2°C) Max.20 psi (137.9 kPA) Min.150 psi (1034.2 kPA) Max. 3/8" Female Pipe ThreadCondenserWater Drain --- --- 1/2" FemalePipe Thread1/2" (1.27 cm) minimuminside diameterBin Drain --- --- 3/4" FemalePipe Thread3/4" (1.91 cm) minimuminside diameterSV3142ELECTRICAL ENTRANCE18” (46 CM) VENT TUBEAIR GAP1/2” (1.3 CM) MINDRAIN ID1/2” DRAIN CONNECTIONPLASTIC FITTING ON OPPOSITESIDE DO NOT APPLY HEATOPEN, TRAPPED ANDVENTED DRAINDO NOT TRAP DRAIN LINE,LEAVE AIR GAP BETWEENDRAIN TUBE AND DRAIN3/8” FPT ICE MAKING WATER INLET FITTING,PLASTIC FITTING ON OPPOSITE SIDE DO NOTAPPLY HEAT1/2” FPT CONDENSER WATER DRAIN(WATER COOLED UNITS ONLY)3/8” FPT CONDENSER WATER INLET(WATER COOLED UNITS ONLY1/2” CPVC SOCKET AUXILLARY BASEDRAIN