Troubleshooting Section 55-10 Part No. 80-1214-3QF2200/QF2300The evaporator and motor / gearbox are separateassemblies. Warranty procedures require replacementof the entire evaporator or motor /gearbox assembly.Separate components are not available, and fieldrebuilding during the warranty period is not allowed.1. Disconnect power and water supply to the icemachine and drain all water from the reservoir andevaporator.2. Remove reservoir retaining pin, water reservoir, icechute, and drain tubing (refer to ComponentRemoval).3. Recover refrigerant and disconnect refrigerationtubing from evaporator.4. Remove foundation-coupling bolts.5. Lift evaporator out of foundation coupling andremove from ice machine.6. Remove spline hub and keyway from evaporator(8 mm hex wrench for coupling set screw).7. Apply anti-seize compound to the shaft and all boltsto ease future disassembly.8. After reinstallation of evaporator, torque foundationbolts to 195-205 inch lbs.REMOVEFOUNDATIONBOLTSSV3017Revised 8/2003Downloaded from www.Manualslib.com manuals search engine