Electrical System Section 66-48 Part No. 80-1214-32. Disconnect bin level probe from control board andcheck continuity (ohms) from the female connectorto the bin level probe.3. Remove bin level probe from ice chute and cleanwith Manitowoc Ice Machine Cleaner and Sanitizer.Rinse well with fresh water, reinstall and monitor theBin light.4. Disconnect bin level probe wire from the controlboard and place a jumper from the bin level terminalto ground.Bin Level Probe Closed or ShortedThe ice machine will not start and the Bin Level light isenergized continuously.1. Verify ice is not in contact with bin level probe.2. Disconnect bin level probe wire from the controlboard.Continuity CauseNo Replace bin level probe.Yes Go to step 3.Control BoardBin Level Light CauseOff Bin level probeneeded cleaning.Flashes Go to step 4.CHECK FOR CONTINUITYCONNECTOR TO GROUND.Control BoardBin Level Light CauseOn Replace bin level probe.FlashesReconfirm control board is notin an 8-minute lockout. Repeatsteps 1 – 4, then replacecontrol board.Control BoardBin Level Light CauseOff Clean bin level probe.On Replace control board.DISCONNECT BIN LEVEL PROBEFROM CONTROL BOARD.Revised 8 / 2003Downloaded from www.Manualslib.com manuals search engine